Click “Login” button to login to the WEB interface of
the device.
Note:
The default IP address of the device is “192.168.1.254”.
The default user name and password of the device are
“admin”.
If the username or password is lost, user can restore it to
factory settings via management software; all modified
configurations will be cleared after restoring to factory
settings, so please backup configuration file in advance.
Please refer to user manual for specific configuration
method of logging in to WEB interface and other
configurations about network management function.
【
Specification
】
Panel
Gigabit M12
LAN Port
10/100/1000Base-T(X), M12(Female),
8-Pin X-Coded, Automatic Flow Control,
Full/half Duplex Mode, MDI/MDI-X
Autotunning; support two groups of
Bypass
Gigabit PoE
M12
10/100/1000Base-T(X), M12(Female),
8-Pin X-Coded, Automatic Flow Control,
Full/half Duplex Mode, MDI/MDI-X
Autotunning;
Single port supports up to 30W PoE
power output, PoE power supply Pin 1
and 3 are positive, 2 and 4 are negative
100M M12
10/100Base-T(X), M12(Female), 4-Pin
D-Coded, Automatic Flow Control,
Full/half Duplex Mode, MDI/MDI-X
Autotunning
100M PoE
M12
10/100base-T(X), M12 (Female), 4-Pin
D-Coded, automatic flow control,
full/half duplex mode, MDI/MDI-X
automatic detection; The single port
supports up to 30W PoE power supply
output. Pin 1 and 3 of PoE power
supply are positive, while pin 2 and 4
are negative
Console port CLI command line management port
(RS-232), M12(Female), 4-Pin D-Coded
Alarm
interface
M12 (Female), 4-Pin D-Coded, support
1 relay alarm output, current load
capability is 1A@30VDC or
0.3A@125VAC
Indicator
Power indicator, alarm indicator, running
indicator, interface indicator, PoE
indicator
Switch Property
Backplane
bandwidth
56G
Packet buffer
size
12Mbit
MAC Address
Table
16K
Power Supply
Model I
M12(Male), 4-Pin A-Coded
24VDC(18~36VDC), support non-
polarity
Model III
M12(Male), 4-Pin A-Coded
24VDC(9~36VDC), support non-polarity
Model II,
Model IV,
Model V,
Model VI
M12(male)
,
4-Pin A-Coded
,
110VDC (66~156VDC), support reverse
connection protection
Power Consumption
Model II
Full-load(Without PoE):
15.8W@110VDC
Full-load(With PoE): 124.6W@110VDC
Working Environment
Working
temperature
-40~75
℃
Storage
temperature
-40~85
℃
Working
humidity
5%
~
95% (no condensation)
Protection
grade
IP67(metal shell)
【
Disposal of Waste Electrical and Electronic
Equipment (WEEE 2012/19/EU)
】
(Applicable in the EU-member states)
The crossed-out wheeled bin
symbol on the equipment or its
packaging indicates that the
product, at the end of its
service life, shall not be mixed
with unsorted municipal waste
but should be collected
separately, in accordance with
local laws and regulations.
A proper separate collection of
end-of-life equipment for the subsequent recycling, treatment
and environmentally compatible disposal, will help prevent
potential damage to the environment and human health,
facilitating the reuse, recycling and/or recovery of its
component materials.
Private users should contact their vendor or municipal waste
management service and ask for disposal information.
Professional users should contact their suppliers and check
the terms of their selling agreement.
This product must not be disposed of with other commercial
waste.