Device Disassembling 

 

Device power off. 

Step 1

 

Unscrew the screw on the wall about 2mm. 

Step 2

 

Lift the device outward slightly; take out the device, 

Step 3

disassembling ends. 

Power Supply Connection

 

 

DC power supply 

This device provides  3-pin  power supply input 
terminal blocks (V-, FG, V+). The power supply 
support anti-reverse protection. 
Power supply range: 9

48VDC 

Note: 

 

Power ON operation: first connect power line to the 
connection terminal of device power supply, then power 
on. 

 

Power OFF operation: first unpin the power plug, then 
remove the power line, please note the operation order 
above.   

Restore Default Settings

 

Setup  is restoring default 
settings  button. Restoring 
default settings  steps as 
follows:  Press and hold the 

setup button, disconnect the power supply and then give the 
device to power up, wait for about 3~4 seconds to restore the 

factory settings. 

Serial Port Connection

 

This device provides 1-port RS-232 or RS-485/422 serial port 
optional. 

 

RS-232 serial port 

RS-232 adopt DB9-Male connecter, the pin 
definition is shown in the follow table: 
 

PIN 

1  2 

8  9 

RS-232 

 

RXD

 

TXD

 

DTR

 

GND

 

DSR

 

RTS

 

CTS

 

 

 

RS-485/422 serial port 

RS-485/422  adopt 5-pin 5.08mm pitch 
industrial terminal blocks. The  pin 
definition is shown in the follow table: 

PIN 

RS-485 

D+ 

D- 

GND 

 

 

RS-422 

T+ 

T- 

GND 

R+ 

R- 

Checking LED Indicator

 

The device provides LED indicators to monitor the device 
working status with a comprehensive simplified 
troubleshooting; the function of each LED is described in the 
table as below: 

LED  Indicate  Description 

PWR 

ON 

The power connection is operating 
normally.

 

OFF 

The power is not connected or is not 
working properly.

 

LINK 

ON 

The Ethernet interface has established an 
active network connection. 

Flashing 

The Ethernet interface is in a network 
activity state. 

OFF 

The Ethernet interface does not establish 
an active network connection. 

Rx/Tx  OFF 

No data or abnormal data is being 
received or transmitted through serial port. 

Flashing  Serial port is receiving or transmitting data. 

Logging in to WEB Interface

 

This device supports WEB management and configuration. 
Computer can access the device via Ethernet interface. The 
way of logging in to device’s configuration interface via IE 
browser is shown as below: 

 

Configure the IP addresses of computer and the 

Step 1

device to the same network segment, and the 
network between them can be mutually accessed. 

 

Enter device’s IP address in the address bar of the 

Step 2

computer browser. 

 

 

Enter device’s username and password in the login 

Step 3

window as shown below. 

 

 

Click “OK” button to login to the WEB interface of 

Step 4

the device. 

Note: 

 

The default IP address of the device is “192.168.1.254”. 

 

The default username and password of the device is 
“admin”. 

 

If the username or password is lost, user can restore it to 
factory settings via device DIP switch or management 
software; all modified configurations will be cleared 