User Manual
3onedata proprietary and confidential 69
Copyright © 3onedata Co., Ltd.
9.3 TCP Client Mode
Background brief
Assuming that the serial port "COM1" of the serial server is working in "TCP client
mode", it initiates a connection with a host PC, and the host can read or send Ethernet
data to a serial device.
When the data transfer is completed, the serial server will automatically shut down the
network connection after 30 seconds.
The parameters of the serial server (TCP client) are as follows:
IP Address: 192.168.1.250
Local Port: 30000
BaudRate: 115200
PairtyBits: None
DataBits: 8
StopBits: 1
The parameters of the host PC (TCP server) are as follows:
IP Address: 192.168.1.61
Local Port: 31000
Operation steps
Setp 1
Configure the IP address of the serial server.
1. Log in to the Web configuration interface and select “Network Setting”.