supply specification to avoid over-voltage damaging the
device.

The device surface temperature is high after running;
please don't directly contact to avoid scalding.

DIN-Rail Mounting

The product adopts 35mm standard DIN-Rail mounting which
is suitable for most industrial scenes, mounting steps as
follows:

Step 1

Check if the DIN-Rail mounting kit is installed firmly.

Step 2

Insert the bottom of DIN-Rail mounting kit (one side
with spring support) into DIN-Rail, and then insert
the top into DIN-Rail.

Tips:
Insert a little to the bottom, lift upward and then insert
to the top.

Step 3

Check and confirm the products is firmly installed
on DIN-Rail, then mounting ends.

Disassembling DIN-Rail

Step 1

Device power off.

Step 2

After lift the device upward slightly, first shift out the
top of DIN-Rail mounting kit, and then shift out the
bottom of DIN-Rail, disassembling ends.

Note before powering on:

Power ON operation: First insert the power supply
terminal block into the device power supply interface,

and then plug the power supply plug contact and power
on.

Power OFF operation: First, remove the power plug,
and then remove the wiring section of terminal block.
Please pay attention to the above operation sequence.

Power Supply Connection

DC power supply

Model I and Model III provide 3-pin 7.62mm
pitch terminal block for 1 DC power input.
This power supply supports anti-reverse
connection Power supply range: 9

48VDC. The pin definitions of power supply are shown as
follows:

Pin No.

1

2

3

Definition

V+

FG

V-

AC power supply

Model II and Model IV provide 3 7.62mm
pitch terminal block for 1 power input.
Power supply range: 100~240VAC/DC.
The pin definitions of power supply are

shown as follows:

Pin No.

1

2

3

Definition

N/-

GND

L/+

DIP Switch Settings

Provide 4-bits DIP switch for function setting,
where "ON" is enable valid terminal. DIP switches
definition as follows:

DIP Definition

Operation

1

Jumbo frame Set the DIP to ON to enable jumbo

frame function

2

Broadcast
storm
suppression

Set the DIP to ON to enable
broadcast storm suppression
function

3

LFP

Set the DIP to ON to enable LFP
function, when one end of the

DIP Definition

Operation

copper port or fiber port
disconnects, close another port;
when the port is reconnected, open
another port.

4

Flow control

Set the DIP to ON to enable flow
control function

Checking LED Indicator

The device provides LED indicators to monitor the device
working

status

with

a

comprehensive

simplified

troubleshooting; the function of each LED is described in the
table as below:

LED

Indicate Description

PWR

ON

PWR is connected normally

OFF

PWR is disconnected or running
abnormally

Link/Act
(1-2)

ON

Ethernet port is connected

Blinking

The Ethernet interface is in a
network activity state.

OFF

Ethernet port is is connected
abnormally or disconnected

Specification

Panel

100M Copper Port

10/100Base-T(X),

RJ45,

Automatic Flow Control, Full/half
Duplex

Mode,

MDI/MDI-X

Autotunning

100M fiber port

100Base-FX, optional SC/ST/FC

100M SFP

100Base-FX SFP slot

Indicator

Power supply indicator, interface
indicator

Switch Property

Backplane bandwidth

1G

MAC Address Table

2K

Power supply