background image

1. 

Power indicator 

2. 

LFP indicator 

3. 

100M interface connection status indicator 

4. 

100Base-FX fiber port 

5. 

10/100Base-T(X) copper port 

6. 

Gigabit interface connection status indicator 

7. 

1000Base-X 1×9 fiber port 

8. 

10/100/1000Base-T(X) copper port 

9. 

1000Base-X SFP slot indicator 

10. 

1000Base-X SFP slot 

11. 

DIN-Rail mounting kit 

12. 

DC power terminal block 

13. 

DIP switch 

14. 

Grounding screw (Protective grounding) 

15. 

AC power terminal block 

Mounting Dimension

 

Unit: mm 

 

Note before mounting:

 

 

Don't place or install the device in area near water or 
moist, keep the relative humidity of the device 
surrounding between 5%~95% without condensation. 

 

Before power on, first confirm the supported power 
supply specification to avoid over-voltage damaging the 
device. 

 

The device surface temperature is high after running; 
please don't directly contact to avoid scalding. 

DIN-Rail Mounting

 

The product adopts 35mm standard DIN-Rail mounting which 
is suitable for most industrial scenes, mounting steps  as 
follows: 

 

Step 1  Check if the DIN-Rail mounting kit is installed firmly. 
Step 2  Insert the bottom of DIN-Rail mounting kit (one side 

with spring support) into DIN-Rail, and then insert the 
top into DIN-Rail. 

Tips: 
Insert a little to the bottom, lift upward and then insert 
to the top. 

Step 3  Check and confirm the product is firmly installed on 

DIN-Rail, then mounting ends. 

Disassembling DIN-Rail

 

Step 1  Device power off. 
Step 2  After lift the device upward slightly, first shift out the 

top of DIN-Rail mounting kit, and then shift out the 
bottom of DIN-Rail, disassembling ends. 

Note before powering on:

 

 

Power ON operation: First insert the power supply 
terminal block into the device power supply interface, 
and then plug the power supply plug contact and power 
on. 

 

Power OFF operation: First, remove the power plug, 
and then remove the wiring section of terminal block. 
Please pay attention to the above operation sequence. 

Power Supply Connection

 

This device provides 3-pin 7.62mm pitch 
terminal block, which supports non-polarity and 
anti-reverse connection. 

Note: 

Before connecting to power supply, confirm the power 
supply type the product supports. 

 

DC power supply 

Voltage range: 24VDC (12~48VDC) 
The pin definitions of DC power supply are shown as follows: 

PIN 

Definition 

V+ 

FG 

V- 

 

AC power supply 

Power supply value: 220VAC 
The pin definitions of AC power supply are shown as follows: 

PIN 

Definition 

FG 

DIP Switch Settings

 

Provide 4 pins DIP switch for function settings, 
where "ON" is enable valid terminal. The device 
needs to be powered on again to change the 

status of DIP switch. DIP switches definition as follows: 

DIP 

ON Status 

OFF Status 

Reserved 

Enable flow control 
function 

Disable flow control 
function 

Set the device to remote 
mode. PWR indicator 
would blink when device 
is in remote mode. 

Set the device to local 
mode. PWR indicator is 
on when device is in 
local mode. 

Reserved 

Checking LED Indicator

 

The device provides LED indicators to monitor the device 
working status with a comprehensive simplified 
troubleshooting; the function of each LED is described in the 
table as below: 

LED 

Indicate  Description 