Front view                              Side view 

 

1. Ground screw   

2. Console port 

3. 2-pin terminal block for relay output 

4. Power input terminal block 

5. DIP switches 

6. DIN-Rail mounting kit 

7. Relay alarm LED   

8. Power indicator 

9. System running LED 

10. Gigabit SFP port   

11. 10Base-T /100Base-TX/1000Base-TX Ethernet port 

12. Link/ACT LEDs 

Power supply input

 

 

The switch top panel provided 4 bit power supply input terminal 

block,  support  DC  input.  DC  power  supply  input  supported 

redundancy  function,  provided  PWR1  and  PWR2  power  input, 

can  use  for  single,  and  can  connect  2  separately  power  supply 

system,  use  1 pair terminal  block  connect  the  device  at  the  same 

time.  If  one  of  the  power  systems  broke,  the  device  can  work 

un-interruptible. 

Built-in 

overcorrect 

protection, 

Reverse 

connection  protection.  Voltage  input  range  is  12

48VDC

terminal block defined as: V1-

V1+

V2-

V2+

Important notice: 

1.

 

Power ON operation: first of all, insert power cable’s terminal 

block into device’s power port, then insert power supply plug into 

power source 

2.

 

Power  OFF  operation:  First  off  all,  unpin  power  plug,  then 

strike the terminal block, please take care of operation sequence. 

 

Dimension

 

Unit (mm)

 

 

 

DIP Switch

 

 

Top  panel  provided  4  bits  DIP  switch  to  do  function  configure

ON to enable effective

, 1, 3 and 4 keep for future function. 2 

is recovery default factory. Please power off  and power on when 

you change the status of DIP switch. 

Relay connection

 

 

Relay access terminals in the top panel of the device. Between the 

two  terminal  relay,  as  an  open  circuit  state  in  normal  non  alarm 

state, when there is any alarm information to the closed state. The 

two terminal block connector are used to detect both power failure 

and port failure. The

 

two wires attached to the Fault contacts form 

an open circuit when the device has lost power supply from one of 

the DC power inputs or one of the ports is failure.   

Console port

 

This  series  switch  provided  1pcs  procedure  test  port  based  in 

serial  port.  It  adopts  RJ45  interface,  located  in  top  panel,  can 

configure related command through RJ45 to DB9 female cable. 

 

Communication connector

 

10/100/1000BaseT(X) Ethernet port 

The pinout of RJ45 port display as below, connect by UTP or STP. 

The  connect  distance  is  no  more  than  100m.  1000Mbps  is  used 

120Ω  of  UTP  5e;  100Mbps  is  used  120Ω  of  UTP  5;  10Mbps  is 

used 120Ω of UTP 3, 4, 5. 

 

RJ  45  port  support  automatic  MDI/MDI-X  operation.  That  can 

connect the PC, Server, Converter and HUB. Pin 1, 2, 3, 4, 5, 6, 7, 

Summary of Contents for IES7112G-4GS

Page 1: ...dustrial Ethernet switch is shipped with the following items If any of these items are missing or damaged please contact your customer service representative for assistance Industrial Ethernet switch 1 Documentation and software CD 1 User manual 1 DIN Rail mounting kit 1 Warranty card 1 Feature Support IEEE802 3 IEEE802 3u IEEE802 3z ab IEEE802 3x IEEE802 1Q IEEE802 1p IEEE802 1W D IEEE802 1s IEEE...

Page 2: ...eration sequence Dimension Unit mm DIP Switch Top panel provided 4 bits DIP switch to do function configure ON to enable effective 1 3 and 4 keep for future function 2 is recovery default factory Please power off and power on when you change the status of DIP switch Relay connection Relay access terminals in the top panel of the device Between the two terminal relay as an open circuit state in nor...

Page 3: ...ame letter A to A and B to B shown as below or A1 to A2 and B1 to B2 LED Indicator LED indictor light on the front panel of product the function of each LED is described in the table as below System indication LED LED State Description P1 ON Power is being supplied to power input PWR1 OFF Power is not being supplied to power input PWR1 P2 ON Power is being supplied to power input PWR2 OFF Power is...

Page 4: ... link Its banding should be moderate not too tight and should be separated from other cables 9 It should have corresponding simple signal at both sides of the cable for maintaining Specification Technology Standard Support IEEE802 3 IEEE802 3u IEEE802 3z ab IEEE802 3x IEEE802 1Q IEEE802 1p IEEE802 1W D IEEE802 1s IEEE802 3ad IEEE802 1X Protocol ARP ICMP TCP DHCP DNS HTTP Telnet SW Ring RSTP MSTP L...

Page 5: ...e W H D 70mm 160mm 130mm Industry Standard EMI FCC Part 15 CISPR EN55022 class A EMS EN61000 4 2 ESD Level 3 EN61000 4 4 EFT Level 3 EN61000 4 5 Surge Level 3 Shock IEC 60068 2 27 Free fall IEC 60068 2 32 Vibration IEC 60068 2 6 Certification CE FCC RoHS UL508 Pending Warranty 5 years ...