100, 101, 102, 103 and 104 are in Ring 2; ring network ports are Port 2 and Port 3;
single ring; 100 is the master station, others are slave stations.
100, 101, 105 and 106 are in Ring 3. It is a coupling ring. Port 1 is coupling port.
Port 2 is control port.
Operation Step 1: configuring Ring 1 in WEB interface
Configuring Device 105, 106, 107, 108 and 109 in the following steps respectively.
Step 1
Choose “Main Menu > Redundancy > Rapid Ring”.
Step 2
In the “Settings” area of “Rapid Ring” page, choose “Ring V3” as “Protocol of
Redundancy”.
Step 3
Check the box of “Enable” in “Group 1”.
Step 4
Choose “Single” in the drop-down list of “Type” of “Group 1”.
Step 5
Enter “1” into the “ID” textbox of “Group 1”.
Step 6
Set “Port 1” and “Port 2” to “02” and “03” respectively.
Description:
“Port 1” and “Port 2” cannot be set to the same port.
Step 7
For Device 106/107/108/109, choose “Slave” in the drop-down list of “Master-slave” of
“Group 1”.
Step 8
For Device 105, choose “Master” in the drop-down list of “Master-slave” of “Group 1”.
Step 9
Click “Apply”. Enter “Main Menu > System Management > Device Address”.
Step 10
On the column of “Device Reboot”, click the button of “Reboot”.
Step 11
End.
Operation Step 2: configuring Ring 2 in WEB interface
Configuring Device 100, 101, 102, 103 and 104 in the following steps respectively.
Step 1
Choose “Main Menu > Redundancy > Rapid Ring”.
Step 2
In the “Settings” area of “Rapid Ring” page, choose “SW-Ring V3” as “Protocol of
Redundancy”.