Instance analysis
The ring ports of Device 100, 101, and 102 are port 1 and port 2. Therefore, creating
single ring is viable. Port 1 and port 2 are set as the ring ports of each device.
Operating steps
Configuring Device 100, 101 and 102 in the following steps:
Step 1
Choose “Main Menu > Redundancy > Rapid Ring”.
Step 2
In the “Settings” area of “Rapid Ring” page, choose “Ring V3” as “Protocol of
Redundancy”.
Step 3
Check the box of “Enable” in “Group 1”.
Step 4
Choose “Single” in the drop-down list of “Type” of “Group 1”.
Step 5
Enter “1” into the “ID” textbox of “Group 1”.
Step 6
Set “Port 1” as “01” and “Port 2” as “02” separately.
Description:
“Port 1” and “Port 2” cannot be set to the same port.
Step 7
For Device 100 and 101, choose “Slave” in the drop-down list of “Master-slave” of