background image

- 3 - 

remote switch’s RX(receive) port; RX(receive) port connect 
remote switch’s TX(transmit) port. 
The optical fiber connection supports the line to instruct 
enhance the reliability of network effectively. 

Suppose

: If you make your own cable, we suggest labeling 

the two sides of the same line with the same letter (A-to-A 
and B-to-B, shown as below, or A1-to-A2 and B1-to-B2). 

 

1000Base SFP fiber port(mini-GBIC) 

1000Base-X  SFP  fiber port adopts gigabit mini-GBIC 
transmission, can choice different SFP module according to 
different transfer distance. Fiber interface must use for pair, 
TX port is transmit side, must connect to RX (receive side). 
The fiber interface support loss line indicator. 

Suppose

: If you make your own cable, we suggest labeling 

the two sides of the same line with the same letter (A-to-A 
and B-to-B, shown as below, or A1-to-A2 and B1-to-B2). 

 

LED Indicator

 

LED indictor light on the front panel of product, the function 
of each LED is described in the table as below. 

System indication LED 

LED 

State 

Description 

P1 

ON 

Power is being supplied to 
power input PWR1 

OFF 

Power is 

not 

being supplied 

to power input PWR1 

P2 

ON 

Power is being supplied to 
power input PWR2 

OFF 

Power is 

not 

being supplied 

to power input PWR2 

Alarm 

ON 

When the alarm is enabled, 
power or the port’s link is 
inactive. 

OFF 

Power and the port’s link is 
active, the alarm is disabled. 

Run 

ON/OFF  System is not running well 
Blinking 

System is running well 

Link/ACT 

(1~16/ 
G1~G4)

 

ON 

Port connection is active 

Blinking 

Data transmitted 

OFF 

Port connection is not active 

Installation

 

Before installation, confirm that the work environment meet 
the installation require, including the power needs and 
abundant space. Whether it is close to the connection 
equipment and other equipments are prepared or not.   
1.  Avoid in the sunshine, keep away from the heat 

fountainhead or the area where in intense EMI. 

2.  Examine the cables and plugs that installation 

requirements. 

3.  Examine whether the cables be seemly or not (less than 

100m) according to reasonable scheme.   

4.  Power: 12 ~ 48VDC power supply. 
5.  Environment: working temperature: -40

75

 

Storage Temperature: -40

85

 

Relative humidity 5%

95% 

DIN Rail Installation 

In order to use in industrial environments expediently, the 
product  adopt 35mm DIN-Rail installation, the installation 
steps as below: 
1.  Examine the DIN-Rail attachment 
2.  Examine DIN Rail whether be firm and the position is 

suitability or not. 

3.  Insert the top of the DIN-Rail into the slot just below the 

stiff metal spring. 

4.  The DIN-Rail attachment unit will snap into place as 

shown below. 

 

Wiring Requirements 

Cable laying need to meet the following requirements,

 

1.  It is needed to check whether the type, quantity and 

specification of cable match the requirement before 
cable laying; 

2.  It is needed to check the cable is damaged or not, factory 

records and quality assurance booklet before cable 
laying; 

3.  The required cable specification, quantity, direction and 

laying position need to match construction requirements, 
and cable length depends on actual position; 

4.  All the cable cannot have break-down and terminal in the 

middle; 

5.  Cables should be straight in the hallways and turning; 
6.  Cable should be straight in the groove, and cannot 

beyond the groove in case of holding back the inlet and 

Summary of Contents for IES3020-4GS-4F-P

Page 1: ... field to achieve high reliability Packing list The industrial Ethernet switch is shipped with the following items If any of these items are missing or damaged please contact your customer service representative for assistance Industrial Ethernet switch 1 User manual 1 DIN Rail mounting kit 1 Warranty card 1 Feature High performance network exchange technology Support IEEE802 3 IEEE802 3u IEEE802 ...

Page 2: ...ere is any alarm information to the open state The two terminal block connector are used to detect power failure The two wires attached to the Fault contacts form an open circuit when the device has lost power supply from one of the DC power inputs is failure Console port The switch provided 1pcs procedure test port based in serial port It adopts RJ45 interface located in top panel can configure r...

Page 3: ...t active Installation Before installation confirm that the work environment meet the installation require including the power needs and abundant space Whether it is close to the connection equipment and other equipments are prepared or not 1 Avoid in the sunshine keep away from the heat fountainhead or the area where in intense EMI 2 Examine the cables and plugs that installation requirements 3 Ex...

Page 4: ... Half full duplex and MDI MDI X auto detect 100M optic fiber port 100Base FX SC ST FC connector Gigabit SFP port 1000Base FX SFP slot Transfer distance Twisted cable 100M standard CAT5 CAT5e cable Multi mode 1310nm 2Km Single mode 1310nm 20 40 60Km 1550nm 80 100 120Km Power supply Input voltage 12 48VDC Type of input 4 bit 7 62mm pitch terminal block Overload Current Protection 4 0A Consumption IE...

Reviews: