background image

- 2 - 

8.  Relay alarm LED   
9.  Power indicator   
10.  Gigabit SFP port   
11.  100Base-FX fiber port   
12.  Link/ACT LEDs 
13.  10Base-T /100Base-TX Ethernet port 

Power supply input

 

 

The  switch  top panel provided 4 bit power supply input 
terminal block, support DC input. DC power supply input 
supported redundancy function, provided PWR1 and PWR2 
power input, can use for single, and can connect 2 
separately power supply system, use 1 pair terminal block 
connect the device at the same time. If one of the power 
systems broke, the device can work un-interruptible. Built-in 
overcorrect protection, Reverse connection protection. 
Voltage input range is 12

48VDC  (terminal block defined 

as: V1-, V1+, V2-, V2+). 

Dimension

 

The series of products are the same size, and the number of 
the Ethernet interface is different. Unit (mm)

 

 

DIP Switch

 

 

Top panel provided 4 bits DIP switch to do function configure 
(ON to enable effective),  1 keep for future function. 2 is 
double power alarm. 3 is flow control. 4 is broadcast storm 
suppress features. Please power off and power on when you 
change the status of DIP switch. 

Relay connection

 

 

Relay access terminals in the top panel of the device. 
Between the two terminal relay, as a closed circuit state in 
normal non alarm state, when there is any alarm information 
to the open state. The two terminal block connector are used 
to detect power failure. The

 

two wires attached to the Fault 

contacts form an open circuit when the device has lost 
power supply from one of the DC power inputs is failure.

 

Console port

 

The switch provided 1pcs procedure test port based in serial 
port. It adopts RJ45 interface, located in top panel, can 
configure related command through RJ45 to DB9 female 
cable. 

 

Communication connector

 

10/100BaseT(X) Ethernet port 

The pinout define of RJ45 port display as below, connect by 
UTP or STP. The connect distance is no more than 100m. 
100Mbps is used 120Ω of UTP 5, 10Mbps is used 120Ω of 

UTP 3, 4, 5. 

 

RJ45 port support automatic MDI/MDI-X operation. can 
connect the PC, Server, Converter and HUB .Pin 1,2,3,6 
Corresponding  connection  in  MDI.  1→3,  2→6,  3→1,  6→2 
are used as cross wiring in the MDI-X port of Converter and 
HUB. 10Base-T/100Base-TX are used in MDI/MDI-X, the 
define of Pin in the table as below. 

NO. 

MDI signal  MDI-X signal 

TX+ 

RX+ 

TX- 

RX- 

RX+ 

TX+ 

RX- 

TX- 

4, 5, 7, 8 

— 

— 

Note

“TX±”Transmit Data±

“RX±”Receive Data±

“—” Not use.

 

10/100Base-T(X) MDI (straight-through cable) 

 

10/100Base-T(X) MDI-X (Cross over cable) 

 

MDI/MDI-X auto connection makes switch easy to use for 
customers without considering the type of network cable. 

100Base-FX Fiber port   

100Base-FX full-duplex SM or MM port, SC/ST/FC type .The 
fiber port must be used in pair, TX (transmit) port connect 

1

8

Summary of Contents for IES3020-4GS-4F-P

Page 1: ... field to achieve high reliability Packing list The industrial Ethernet switch is shipped with the following items If any of these items are missing or damaged please contact your customer service representative for assistance Industrial Ethernet switch 1 User manual 1 DIN Rail mounting kit 1 Warranty card 1 Feature High performance network exchange technology Support IEEE802 3 IEEE802 3u IEEE802 ...

Page 2: ...ere is any alarm information to the open state The two terminal block connector are used to detect power failure The two wires attached to the Fault contacts form an open circuit when the device has lost power supply from one of the DC power inputs is failure Console port The switch provided 1pcs procedure test port based in serial port It adopts RJ45 interface located in top panel can configure r...

Page 3: ...t active Installation Before installation confirm that the work environment meet the installation require including the power needs and abundant space Whether it is close to the connection equipment and other equipments are prepared or not 1 Avoid in the sunshine keep away from the heat fountainhead or the area where in intense EMI 2 Examine the cables and plugs that installation requirements 3 Ex...

Page 4: ... Half full duplex and MDI MDI X auto detect 100M optic fiber port 100Base FX SC ST FC connector Gigabit SFP port 1000Base FX SFP slot Transfer distance Twisted cable 100M standard CAT5 CAT5e cable Multi mode 1310nm 2Km Single mode 1310nm 20 40 60Km 1550nm 80 100 120Km Power supply Input voltage 12 48VDC Type of input 4 bit 7 62mm pitch terminal block Overload Current Protection 4 0A Consumption IE...

Reviews: