3onedata IES3016L Series Instruction Manual Download Page 3

MDI-X (crossover cable)

100Base-FX Fiber Port

100Base-FX fiber port needs to be used in pairs. TX is

transmission side to connect to receiving side RX in remote

switch;

Suppose

: If you make your own cable, we suggest labeling

the two sides of the same line with the same letter (A-to-A and

B-to-B, shown as below, or A1-to-A2 and B1-to-B2).

LED Indicator

LED indictor is in the front panel of IES3016L. The function

of each LED is described in the table as below.

System indication LED

LED

state

Description

PWR1

ON

Power 1 is working.

OFF

PWR1 is not connected or does

not run normally.

PWR2

ON

Power 2 is working.

OFF

PWR2 is not connected or run

normally.

Alarm

ON

Power or port link is broken or

failure.

OFF

power and port link is working

well

SYS

ON/OF

F

Device does not run normally

Blink

Device runs well.

Link1~16

ON

Network connection of the port

is valid

Blink

Data is being transmitted

OFF

Network connection of the port

is invalid

Installation

Before

installation,

please

confirm

that

the

work

environment meet the installation requirement, including the

power needs and abundant space, whether it is close to the

connection equipment and other equipments are prepared or not.

Examine the cables and plugs that installation requirements.

Examine whether the cables be suitable or not (less than 100m)

according to reasonable scheme.

Screw, nut, tool provided by yourself.

Power

need:

Redundant,

dual

24VDC

power

inputs(12~48DC

Environment: -40°C to 75°C

Relative humidity 5% to 95%

Wiring Requirements

Wiring need to meet the following requirements:

It is needed to check whether the type, quantity and

specification of cable match the requirement before

cable laying;

It is needed to check the cable is damaged or not, factory

records and quality assurance booklet before cable

laying;

The required cable specification, quantity, direction and

laying position need to match construction requirements,

and cable length depends on actual position;

All the cable cannot have break-down and terminal in

the middle;

Cables should be straight in the hallways and turning;

Cable should be straight in the groove, and cannot

beyond the groove in case of holding back the inlet and

outlet holes. Cables should be banded and fixed when

they are out of the groove;

User cable should be separated from the power lines.

Cables, power lines and grounding lines cannot be

overlapped and mixed when they are in the same groove

road. When cable is too long, it cannot hold down other

cable, but structure in the middle of alignment rack;

Pigtail cannot be tied and swerved as less as possible.

Swerving radius cannot be too small (small swerving

causes terrible loss of link). Its banding should be

moderate, not too tight, and should be separated from

other cables;

It should have corresponding simple signal at both sides

of the cable for maintaining.