Step 3
Enter device’s username and password in the
login window as shown below.
Step 4
Click “OK” button to login to the WEB interface of
the device.
Note:
The default IP address of the device is
“192.168.1.254”.
The default username and password of the device are
“admin123”.
If the username or password is lost, user can restore it
to factory settings via device DIP switch or
management software; all modified configurations
will be cleared after restoring to factory settings, so
please backup configuration file in advance.
Please refer to user manual for specific configuration
method of logging in to WEB interface and other
configurations about network management function.
【
Specification
】
Panel
10GbE interface
10GbE SFP+ port (10Gigabit /
Gigabit self-adaption)
1000M Combo port
10/100/1000Base-T(X) RJ45
or 100/1000 Base-X SFP
interface (optional)
Gigabit SFP
100/1000Base-X SFP slot
Console port
CLI command management
port (RS-232), RJ45
Alarm interface
5-pin 5.08mm pitch terminal
block (R+/R-), support 2 relay
alarm information outputs
Indicator
Power indicator, system alarm
indicator, device running
status indicator, interface
connection/running status
indicator
Switch Property
Backplane bandwidth
168G
Buffer size
16Mbit
MAC address table
16K
Power Supply
Model I
Input power: 100~240VAC/DC
Access terminal: support
single-phase socket with
rocker switch
Model II
Input power: 18~72VDC
Access terminal: adopt 5-pin
5.08mm pitch terminal blocks
(power supply occupies 3
pins)
Power Consumption
Model I
No-load: 21.1W@220VAC
Full-load:37.8W@220VAC
Working Environment
Working temperature
-40~75
℃
Storage temperature
-40~85
℃
Working humidity
5%
~
95% (no condensation)
Protection grade
IP40 (metal shell)
【
Disposal of Waste Electrical and Electronic
Equipment (WEEE 2012/19/EU)
】
(Applicable in the EU-member states)
The crossed-out wheeled bin
symbol on the equipment or
its packaging indicates that
the product, at the end of its
service life, shall not be
mixed with unsorted
municipal waste but should
be collected separately, in
accordance with local laws
and regulations.
A proper separate collection of end-of-life equipment for the
subsequent recycling, treatment and environmentally
compatible disposal, will help prevent potential damage to
the environment and human health, facilitating the reuse,
recycling and/or recovery of its component materials.
Private users should contact their vendor or municipal waste
management service and ask for disposal information.
Professional users should contact their suppliers and check
the terms of their selling agreement.
This product must not be disposed of with other commercial
waste.
Users’ cooperation in the correct disposal of this product will
contribute to saving valuable resources and protecting the
environment.