3onedata ICS5530 Series Quick Installation Manual Download Page 2

 

Step 3 

Place the device in the rack; adopt 4 bolts to fix 
two sides mounting lugs in the rack. 

 

Step 4 

Check and confirm the product is mounted firmly 
on the rack, then mounting ends. 

Disassembling Device

 

Step 1 

Power off the device. 

Step 2 

Adopt screw driver to loosen the 4 bolts fixed on 

the mounting lugs in the rack. 

Step 3 

Shift out the device from rack, disassembling 

ends. 

Notice before Powering on: 

 

Power ON operation: First insert the power supply 
terminal block into the device power supply interface, 
and then plug the power supply plug and power on. 

 

Power switch “—” means power ON, “O” means 
power OFF. 

 

Power OFF operation: First, put the powers switch to 
the "O" side and then disconnect the power supply. 
Finally disconnect the connector between the device 
and the power cord. Please notice the operation order 
above. 

Power Supply Connection

 

 

AC power supply 

Model I provides 2 AC power supply access 
interfaces which come with a switch.

 

Power supply range: 100~240VAC/DC. 

 

DC power supply 

Model II  supports 2 DC power input 
interfaces, and adopts 5-pin 5.08mm 
pitch terminals, and the power supply 

occupies the left 3 pins. The power supply supports 
anti-reverse connection and dual power supply redundancy, 
and the pin definitions of power supply are shown in the left 
figure. Power input range: 18

72VDC. 

Restore Default Settings

 

RESET is restoring default settings button. Device Restoring 
default settings steps as follows: press and hold the RESET 
button, power on the device again, wait for about 3~4 
seconds to restore the factory settings. 

Relay Connection

 

R+ and R-  are  the relay alarm output 
section. They are open circuit in normal 
non alarm state, closed when any alarm 

information occurs. The product supports 2-way relay alarm 
output, externally connected to alarm lights or alarm buzzer 
or other switching value collecting device in order to timely 
notify operators when the alarm occurs.

 

Console Port Connection

 

The device provides 1 program debugging port based on 
RS-232 serial port which can conduct device CLI command 
management after connecting to PC. The interface adopts 
RJ45 port, and the RJ45 pin definitions are as follows: 

Pin No. 

Definition 

TXD 

RXD 

GND 

Checking LED Indicator

 

The series product provides LED indicators to monitor the 
device working status with a comprehensive simplified 
troubleshooting; the function of each LED is described in the 

table as below: 

LED 

Indicate 

Description 

P1 

ON 

PWR is connected and 
running normally 

OFF 

Power supply is disconnected 
or running abnormally 

P2 

ON 

PWR is connected and 
running normally 

OFF 

Power supply is disconnected 
or running abnormally 

RUN 

Blinking 

The system is running 
normally 

OFF 

The system is not running or 
running abnormally 

ON 

System is running abnormally 

ALM 

ON 

Power supply, port link alarm 

OFF 

Power supply, port link without 
alarm 

Link 
(G1-G24, 
X1-X6) 

ON 

Port has established valid 
network connection 

Blinking 

Port is in a network 
communication status 

OFF 

Port hasn’t established valid 
network connection. 

Logging in to WEB Interface

 

This device supports WEB management and configuration. 
Computer can access the device via Ethernet interface. The 
way of logging in to device’s configuration interface via IE 
browser is shown as below. 
Step 1 

Configure the IP addresses of computer and the 
device to the same network segment, and the 
network between them can be mutually 
accessed. 

Step 2 

Enter device’s IP address in the address bar of 
the computer browser. 

 

Reviews: