Pin NO. 

Definition 

NC  RX+  RX-  TX+  GND  GND  TX-  NC 

LED Indicator

 

The device provides LED indicators  for  monitoring  device’s 
operating status, which  has  simplified  the overall 
troubleshooting  process.  The function of each LED is 
described in the table as below: 

LED 

Status  Description 

PWR 

ON 

PWR is connected and running 
normally 

OFF 

PWR is disconnected and 
running abnormally. 

LINK 

ON 

Ethernet port is connected. 

OFF 

Ethernet port is disconnected. 

DUP 

ON 

Ethernet port is in full duplex 
mode. 

OFF 

Ethernet port is in half duplex 
mode. 

10M/ACT 

ON 

Ethernet port rate is 10Mbps 

Blinking  Data is being transmitted through 

Ethernet port. 

100M/ACT 

ON 

Ethernet port rate is 100Mbps 

Blinking  Data is being transmitted through 

Ethernet port. 

(1-4) 
E1-WORK 

ON 

(1-4) E1 port is running normally 

OFF 

(1-4) E1 port is running 
abnormally 

(1-4) 
E1-LOS 

ON 

(1-4) E1 port signal interruption 
alarm 

OFF 

(1-4)  E1  port is normally 
connected     

PTOK 

ON 

Pseudorandom  loopback test 
succeeded 

OFF 

Loopback test is operating or off.   

TEST 

ON 

E1 port is in loopback test status   

OFF 

No  E1  port is in loopback test 
status   

Specification

 

Panel 

 

Ethernet port 

1-way 10/100M, full/half 
duplex can configure RJ45 
port 

E1 port 

4-way E1, optional 75

Ω

 BNC 

port or 120

Ω

 RJ45 port 

(rack-mounted) 

Indicator 

Power indicator, Ethernet 
indicator, E1 indicator, 
loopback test status indicator 

Power supply

 

 

Input power supply

 

220VAC (desktop) 
Optional 220VAC or -48VDC 
(rack-mounted) 

Connection terminal   

220VAC: 3-hole socket 
-48VDC: 3-pin terminal 
blocks. 

Power consumption 

 

Full-load 

2W 

Operating temperature 

 

Operating temperature

 

-25~70

 

Storage temperature

 

-40~85

 

Operating humidity

 

5%~95%(no condensation) 

 