device. 

 

The device surface temperature is high after running; 
please don't directly contact to avoid scalding. 

Rack-mounted

 

Mounting the device 

Step 1 

Select the device mounting location to ensure 
enough size. 

Step 2 

Place the device on the rack surface plate; adopt 4 
screws to mount the right and left mounting lugs on 
the rack. 

 

Step 3 

Check and confirm the product is mounted firmly on 
the rack, mounting ends. 

Device disassembling 

Step 1 

Device powers off. 

Step 2 

Unscrew the fixed mounting lug screw on the rack. 

Step 3 

Shift out the device from rack, disassembling ends. 

Power Supply Connection

 

AC power supply input 

The device supports 1-way  AC power 
supply input. It provides 3-hole socket and AC 
power supply switch. Power supply input range: 

220VAC 

DC power supply input 

The rack-mounted  device  supports  1-way 
220VAC power supply input or 1-way -48VDC 
power supply input. It provides 3-pin  power 

supply input terminal blocks. Power supply input  range: 
-48VDC. Its pin definition is as follows: 

Pin NO. 

Definition 

-48VDC 
cathode 

FG  frame 
GND   

-48VDC 
anode   

  Note: 

 

Power ON operation: first connect power line to the 
connection terminal of device power supply, then power 
on. 

 

Power OFF operation: first unpin the power plug, then 
remove the power line, please note the operation order 
above.   

DIP Switch Setting

 

The device provides 2 sets of 
DIP switches for Ethernet port, 
clock modes and loopback test 

setting. Its definition is as follows: 

Note:

 

The  DIP  switch  definitions  of  rack-mounted and 
desktop device  are  different;  please  refer to  the 
corresponding setting function.   

Rack-mounted 

The setting function of SW1 is as follows:   

NO. 1  NO. 2  NO. 3 

Ethernet port mode setting 

OFF  OFF  OFF  10/100M, full/half duplex self-adaption 
OFF  ON 

OFF  10/100M self-adaption, half duplex 

OFF  OFF  ON 

10M, full/half duplex self-adaption 

OFF  ON 

ON 

10M, half duplex 

ON 

OFF  OFF  100M, full duplex 

ON 

ON 

OFF  100M, half duplex 

ON    OFF  ON 

10M, full duplex 

ON    ON 

ON 

10M, half duplex 

No. 4 

Clock mode setting 

OFF  This end is set as slave clock 
ON 

This end is set as master clock 

The setting function of SW2 is as follows:   

NO. 1  E1 loopback test 

enablement 

No. 2  E1loopback test type 

OFF  Turn off loopback test  OFF  Local loopback 
ON 

Turn on loopback test  ON  Remote loopback 

No. 3  No. 4 

Loopback test E1 channel 
selection setting   

ON 

ON 

Select No. 1 E1 

OFF  ON 

Select No. 2 E1 

ON 

OFF 

Select No. 3 E1 

OFF  OFF 

Select No. 4 E1 

Desktop   

The setting function of SW1 is as follows: 

No. 1 

E1 loopback test 

enablement 

No. 2  E1 loopback test type 

OFF  Turn off loopback test  OFF  Local loopback 
ON 

Turn on loopback test  ON  Remote loopback 

No. 3  No. 4 

Loopback test E1 channel 
selection setting 

ON 

ON 

Select No. 1 E1 

ON 

OFF 

Select No. 2 E1 

OFF  ON 

Select No. 3 E1 

OFF  OFF 

Select No. 4 E1 

No. 8 

Clock mode setting 

OFF  Recover clock   
ON 

Local clock 

The setting function of SW2 is as follows:   

No. 3  No. 4  No. 5 

Ethernet port mode setting 

OFF  OFF  OFF  10/100M, full/half duplex self-adaption 
OFF  ON 

OFF  10/100M self-adaption, half duplex 

OFF  OFF  ON 

10M, full/half duplex self-adaption 

OFF  ON 

ON 

10M, half duplex 

ON 

OFF  OFF  100M, full duplex 

ON 

ON 

OFF  100M, half duplex 

ON    OFF  ON 

10M, full duplex 

ON    ON 

ON 

10M, half duplex 

E1 Port

 

The E1 port of rack-mounted device provides 
two  connection  ways, asymmetrical 75

Ω

 

BNC port and symmetrical  120

Ω

  RJ45 port. 

The pin definition of E1 RJ45 is as follows:   
 