LED Indicator

 

LED  indictor  light  on  the  front  panel  of  product,  the  function  of 

each LED is described in the table as below. 

 

LED 

STATE 

INDICATION 

PWR

 

(Power) 

 OFF 

 Power Off 

 BRIGHT 

 Power On 

FX

 

(Fiber Link Port) 

 OFF 

Ethernet is not Connected 

BRIGHT 

Ethernet is Connected 

100M

 

(10/100M) 

 OFF 

 10M Ethernet 

 BRIGHT 

 100M Ethernet 

1000M

 

 OFF 

 Not 1000M Ethernet 

 BRIGHT 

 1000M Ethernet 

DUP

 

(Duplex Mode) 

 OFF 

 Half Duplex 

 FLASHING  Full Duplex 

TP-TX

 

(Ethernet Port) 

 OFF 

 Ethernet is not Connected 

 FLASHING  Transmitting or Receiving Data 

 BRIGHT 

 Ethernet is Connected 

Installation

 

Model3012  provides  DIN-rail  (optional  accessories)  and  wall 

mounting two types of installation. 

Wall mounting installation

 

Unit: mm 

 

DIN-Rail Installation 

 

 

Wiring Requirements 

Cable laying need to meet the following requirements,

 

1.

 

It  is  needed  to  check  whether  the  type,  quantity  and 

specification  of  cable  match  the  requirement  before  cable 

laying; 

2.

 

It  is  needed  to  check  the  cable  is  damaged  or  not,  factory 

records and quality assurance booklet before cable laying; 

3.

 

The  required  cable  specification,  quantity,  direction  and 

laying position need to match construction requirements, and 

cable length depends on actual position; 

4.

 

All  the  cable  cannot  have  break-down  and  terminal  in  the 

middle; 

5.

 

Cables should be straight in the hallways and turning; 

6.

 

Cable should be straight in the groove, and cannot beyond the 

groove  in  case  of  holding  back  the  inlet  and  outlet  holes. 

Cables  should  be  banded  and  fixed  when  they  are  out  of  the 

groove; 

7.

 

User cable should be separated from the power lines. Cables, 

power  lines  and  grounding  lines  cannot  be  overlapped  and 

mixed when they are in the same groove road. When cable is 

too long, it cannot hold down other cable, but structure in the 

middle of alignment rack; 

8.

 

Pigtail  cannot  be  tied  and  swerved  as  less  as  possible. 

Swerving  radius  cannot  be  too  small  (small  swerving  causes 

terrible loss of link). Its banding should be moderate, not too 

tight, and should be separated from other cables; 

9.

 

It should have corresponding simple signal at both sides of the 

cable for maintaining. 

Specification

 

Standards: IEEE802.3, IEEE802.3u, IEEE 802.3ab, IEEE802.3z 

Interface 

Electric  port:  10Base-T/100Base-TX/1000Base-TX  auto  speed 

control, Half/full duplex and MDI/MDI-X auto detect 

1000M optic fiber port: 1000Base-FX, SC/ST/FC connector 

Transfer distance 

Twisted cable: 100M (standard CAT5/CAT5e cable) 

Multi-mode:850nm/1310nm, 500m/2Km 

Single-mode: 1310nm, 10/20/40Km 

                      1550nm, 60/80/100Km 

Fiber optic cables: 

Single Mode:8.3/125,8.7/125,9/125 or 10/125 um 

Muti-Mode: 62.5/125, 50/125 um 