background image

Your Serial and Data Communications Expert

Shenzhen 3onedata Technology Co.,Ltd

IES205

IES205

IES205

IES205

5-port

5-port

5-port

5-port Entry-level

Entry-level

Entry-level

Entry-level Industrial

Industrial

Industrial

Industrial Ethernet

Ethernet

Ethernet

Ethernet Switch

Switch

Switch

Switch

Hardware

Hardware

Hardware

Hardware Installation

Installation

Installation

Installation Guide

Guide

Guide

Guide

IIIIntroduction

ntroduction

ntroduction

ntroduction::::

The IES205 series of industrial Ethernet switches are entry-level

industrial 5-port Ethernet switches that provide an economical

solution

for

your

industrial

Ethernet

connection,

support

IEEE802.3/802.3u/802.3x. Dustproof and full close structure and

the IP30 case with LED indicators make the plug-and-play IES205

switches easy to use and reliable. These switches have been

designed for harsh industrial environments

IES205 series support 5 ports10/100Base-T(X), Full/Half duplex

mode, and auto MDI/MDI-X connection.

Packing

Packing

Packing

Packing L

L

L

List

ist

ist

ist::::

The IES205 switch is shipped with following items.

1. Ethernet switch IES205 (plus terminal block)

×

1

2. Hardware Installation Guide

×

1

3. Product Warranty Statement

×

1

4. DIN-Rail setting fittings(wall mounting for optional)

F

F

F

Features:

eatures:

eatures:

eatures:

1. IEEE802.3/ 802.3u/ 802.3x

2. Support auto negotiation speed, F/H duplex mode, and auto send

data control

3. Plug-and-play , auto MDI/MDI-X connection

4. Store and Forward 100M

5. Switching process type

6. Broadcast storm protection

7. Network work state LED indicator

8. 12

36VDC

power input

Operating temperature ranges from

-40 to 75°C

9. Industry standard design, dustproof and close design IP30,

rugged

Summary of Contents for IES205

Page 1: ...cators make the plug and play IES205 switches easy to use and reliable These switches have been designed for harsh industrial environments IES205 series support 5 ports10 100Base T X Full Half duplex mode and auto MDI MDI X connection Packing Packing Packing Packing L L L List ist ist ist The IES205 switch is shipped with following items 1 Ethernet switch IES205 plus terminal block 1 2 Hardware In...

Page 2: ...anel anel anel anel Layout Layout Layout Layout IES205 series industry Ethernet switches provide 5 TP ports Power Power Power Power input bottom input bottom input bottom input bottom F F F Front ront ront ront panel panel panel panel T T T Top op op op panel panel panel panel Units Units Units Units mm mm mm mm ...

Page 3: ... used 100Ωof UTP 3 4 5 RJ 45 port support automatic MDI MDI X operation can connect the PC Server Converter and HUB Pin 1 2 3 6 Corresponding connection in MDI 1 3 2 6 3 1 6 2 are used as cross wiring in the MDI X port of Converter and HUB 10Base T 100Base TX are used in MDI MDI X the define of Pin in the table as below NO NO NO NO MDI MDI MDI MDI signal signal signal signal MDI X MDI X MDI X MDI ...

Page 4: ...ndication LED LED State Description POWER ON Power is being supplied to power input POWER1 input OFF Power is not being supplied to power input POWER1 input OFF abnormality RJ45 Port have two LED indictor light yellow light is a port rate indictor light green light is a port link indictor light 10 100M yellow On 100M work mode 100Base TX Off 10Mwork mode 10Base T Link ACT green On TP port is activ...

Page 5: ...as below below below below 1 Avoid in the sunshine keep away from the heat fountainhead or the area where in intense EMI 2 Examine the cables and plugs that installation requirements 3 Examine whether the cables be seemly or not less than 100m according to reasonable scheme 4 Screw nut tool provide by yourself 5 Power need 24VDC 12VDC 36VDC power input 6 Environment 40 to 75 C Storage Temperature ...

Page 6: ...d also pay attention to the following items 1 Use separate path to route wiring for power and devices If power wiring and device wiring paths must cross make sure the wires are perpendicular at the intersection point 2 NOTE Do not run signal or communications wiring and power wiring in the same wire conduit To avoid interference wires with different signal characteristics should be routed separate...

Page 7: ...oltage 12VDC 36VDC Overload Current Protection Connection 3 bit terminal block Mechanical Mechanical Mechanical Mechanical Dimensions L W H 103mm 78mm 32mm Packaging IP 30 Protection Metal case Installation DIN Rail Wall Mounting Environmental Environmental Environmental Environmental Operating Temperature 40 to 75 C Storage Temperature 45 to 85 C Ambient Relative Humidity 10 to 95 non condensing ...

Page 8: ...gy Co Ltd Certifications Certifications Certifications Certifications Shenzhen Shenzhen Shenzhen Shenzhen 3onedata 3onedata 3onedata 3onedata Technology Technology Technology Technology Co Ltd Co Ltd Co Ltd Co Ltd Tel 86 755 26702688 Fax 86 755 26703485 www 3onedata com ...

Page 9: ...Your Serial and Data Communications Expert Shenzhen 3onedata Technology Co Ltd ...