Installation

 

Before installation, confirm that the work environment meet the installation require, including the power needs and abundant space. Whether it is close 

to the connection equipment and other equipments are prepared or not.   

1. Avoid in the sunshine, keep away from the heat fountainhead or the area where in intense EMI.

 

2. Examine the cables and plugs that installation requirements.

 

3. 

Examine whether the cables be seemly or not (less than 100m) according to reasonable scheme.

  

4. Screw, nut, tool provide by yourself. 

5.Power need: 24VDC power inputs(12~48DC

 

6. Environment: -25°C to 70°C 

Relative humidity 10% to 95% 

DIN Rail Installation 

In order to use in industrial environments expediently, IES2010-2GS-4F series adopt 35mm DIN-Rail installation, the installation steps as below, 

1. Examine the DIN-Rail attachment 

2. Examine DIN Rail whether be firm and the position be suitability or not. 

3. Insert the top of the DIN-Rail into the slot just below the stiff metal spring. 

4. The DIN-Rail attachment unit will snap into place.   

 

   

Wiring Requirements 

Cable laying need to meet the following requirements,

 

1. It is needed to check whether the type, quantity and specification of cable match the requirement before cable laying; 

2.    It is needed to check the cable is damaged or not, factory records and quality assurance booklet before cable laying; 

3. The required cable specification, quantity, direction and laying position need to match construction requirements, and cable length depends on 

actual position; 

4. All the cable cannot have break-down and terminal in the middle; 

5. Cables should be straight in the hallways and turning; 

6.  Cable  should  be  straight  in  the  groove,  and  cannot  beyond  the  groove  in  case  of  holding  back  the  inlet  and  outlet  holes.  Cables  should  be 

banded and fixed when they are out of the groove; 

7. User cable should be separated from the power lines. Cables, power lines and grounding lines cannot be overlapped and mixed when they are in 

the same groove road. When cable is too long, it cannot hold down other cable, but structure in the middle of alignment rack; 

8. Pigtail  cannot be  tied  and  swerved  as  less  as  possible.  Swerving  radius  cannot be  too  small  (small  swerving  causes  terrible  loss  of  link).  Its 

banding should be moderate, not too tight, and should be separated from other cables; 

9. It should have corresponding simple signal at both sides of the cable for maintaining. 

Specification

 

Technology 

Standard

IEEE802.3

IEEE802.3u

IEEE802.3x

IEEE802.3z 

Transmit Rate

148810pps 

Max Rate of Filtrate

148810pps 

Processing type: Store and Forward 

MAC address

8K 

Interface 

RJ45 port

10/100BaseT(X) auto connection, Full /Half duplex or force work mode, and support MDI/MDI-X connection 

Fiber port

100BaseFX ports (SC/ST connector, optional) 

Single-mode: 20, 40,60, 80, 100,120Km,optional 

Multi-mode: 2Km, optional. 1000BaseSX/LX/LHX/ZX

LC connector

 

Wavelength: 850nm, 1310 nm, 1550nm 

Power 

24VDC power input

12

48VDC

 

Consumption is less than 8.1W 

Overload Current Protection 

 

 

Summary of Contents for IES2010-2GS-4F

Page 1: ...type in accommodation with limit temperature 40 75 C and we have got CE FCC approvals Packing List The IES2010 2GS 4F series switch is shipped with following items IES2010 2GS 4F Ethernet switch Plus Terminal Block 1 Hardware Installation Guide 1 DIN Rail setting fittings wall mounting for optional Features Support IEEE802 3 IEEE802 3u IEEE802 3x IEEE802 3z Plug and play MDI MDI X auto connection ...

Page 2: ...45 port support automatic MDI MDI X operation can connect the PC Server Converter and HUB Pin 1 2 3 6 Corresponding connection in MDI 1 3 2 6 3 1 6 2 are used as cross wiring in the MDI X port of Converter and HUB 10Base T 100Base TX are used in MDI MDI X the define of Pin in the table as below NO MDI signal MDI X signal 1 TX RX 2 TX RX 3 RX TX 6 RX TX 4 5 7 8 Note TX Transmit Data RX Receive Data...

Page 3: ...or light on the front panel of IES2010 2GS 4F Series the function of each LED is described in the table as below Power Input IES2010 2GS 4F Ethernet switch provides 4 bits industrial terminal blocks V1 V1 V2 V2 V V is 12VDC 48VDC power input System Indication LED LED State Description ON Power is being supplied to power input PWR input PWR green OFF Power is not being supplied to power input PWR i...

Page 4: ...irection and laying position need to match construction requirements and cable length depends on actual position 4 All the cable cannot have break down and terminal in the middle 5 Cables should be straight in the hallways and turning 6 Cable should be straight in the groove and cannot beyond the groove in case of holding back the inlet and outlet holes Cables should be banded and fixed when they ...

Page 5: ... Humidity 5 95 non condensing Approvals Safety UL508 Certifications Shenzhen 3onedata Technology Co Ltd Tel 86 755 26702688 Fax 86 755 26703485 www 3onedata com EMI FCC Part 15 CISPR EN55022 class A EMS EN61000 4 2 ESD Level 4 EN61000 4 3 RS Level 3 EN61000 4 4 EFT Level 4 EN61000 4 5 Surge Level 4 EN61000 4 6 CS Level 3 EN61000 4 8 Shock IEC 60068 2 27 Free Fall IEC 60068 2 32 Vibration IEC 60068...

Reviews: