motion unit ( x) is used.
②
When the starting position is set to the upper right or lower left of the printable area using
ESC T
, the vertical motion
unit ( y) is used.
③
The maximum right-side spacing is 255/180 inches for the paper roll and is approximately 35.983 mm {255/150
inches}. Any setting exceeding the maximum is converted to the maximum automatically.
[Default] n1 = 0, n2 = 0
[Reference]
GS P
FS W n
[Name] Turn quadruple-size mode on/off for Kanji characters
[Format] ASCII FS W n
Hex 1C 57 n
Decimal 28 87 n
[Range] 0
≤
n
≤
255
[Description] • Turns quadruple-size mode on or off for Kanji characters.
• When the LSB of n is 0, quadruple-size mode for Kanji characters is turned off.
• When the LSB of n is 1, quadruple-size mode for Kanji characters is turned on.
[Details] • Only the lowest bit of n is valid.
• In quadruple-size mode, the printer prints the same size characters as when double-width and double-height modes
are both turned on.
• When quadruple-size mode is turned off using this command, the following characters are printed in normal size.
• When some of the characters on a line are different in height, all the characters on the line are aligned at the baseline.
•
FS
! or
GS
! can also select and cancel quadruple-size mode by selecting double-height and double-width modes, and
the setting of the last received command is effective.
[Default] n = 0
[Reference]
FS !, GS !
The printer features a command prompt
ESC B n t
[Name] Printer to print single Beeper
[Format] ASCII ESC B n t
Hex 1B 42 n t
Decimal 27 66 n t
[Range] 1 <= n <= 9,1 <= t <= 9
[Description] • printer to print single Beeper.
• n is the number of times the buzzer.
• t is the number of tweets buzzer each time (t × 50) ms
ESC C m t n
[Name] Printer to print single Beeper and alarm light flashes
[Format] ASCII ESC C m t n
Hex 1B 43 m t n
Decimal 27 67 m t n
Range] 1 <= m <= 20,1 <= t <= 20,0 <= n <= 3,
[Description] •printer to print single Beeper and alarm lights blinking.
• m: 1 <= m <= 20, refers to the warning light flashes the number of times or buzzer.
• t: 1 <= t <= 20, refers to the warning lights flashing at intervals of t * 50 ms or buzzer interval of (t × 50) ms.
• When n = 0, the buzzer does not beep while warning light does not blink;
• When n = 1, the buzzer sounds; when n = 2, warning lights flashing;
• When n = 3, the buzzer sounds, while warning lights flashing;
Programmer