84
6 Output Log
In order to enable logging status data, please enable log setting through [File]
[Log]. It does not record log
data when it is unchecked.
Output folder : (PJman installed folder)\Log\
Filename :
TCP / IP network --- (IP address)_(Port No.).log (ex: 192.168.1.10_23.log)
Serial (RS232C)
---
COMM_(Port
No.).log (ex:
COMM_1.log)
Format :
Command log
[Cmd ], [Date], [Action code], [Operation ID], [Operation Name], [Setting Value], [Result], [Return Value]
Status log (only status is changed)
[Stat], [Date], [Status Name], [Status]
Example
[Stat], 2008/11/07 20:06:16, Power Status, ON
[Stat], 2008/11/07 20:06:16, Lamp Time, 0
[Stat], 2008/11/07 20:06:16, Filter Time, 0
[Stat], 2008/11/07 21:06:16, Lamp Time, 1
[Stat], 2008/11/07 21:06:16, Filter Time, 1
[Cmd ], 2008/11/07 21:10:35, Set, 0x2000, Input Source, 1, OK, 0
[Cmd ], 2008/11/07 21:15:27, Get, 0x6000, Power, 0, OK, 0
[Cmd ], 2008/11/07 21:15:27, Set, 0x6000, Power, 0, OK, 0
[Stat], 2008/11/07 21:15:30, Error Status, Disconnect
© 3M 2012. All Rights Reserved.