3M WS Aware CTC061 User Manual Download Page 4

4

To reduce the risks associated with hazardous voltage and fire:
•   Do not use the power supply if damaged. Replace power supply if damaged using only 3M supplied parts.
•   Do not attempt to service the power supply or monitor, there are no user serviceable parts; return to  

3M for service.

•   Do not position the monitor or other equipment where unplugging the power supply is difficult. Always 

locate the power socket or outlet near the equipment. The power supply plug serves as the disconnect 
device.

•   Do not use the 3M

 WS Aware Workstation Monitor or its power supply outside of the operating conditions 

listed in this user guide.

To reduce the risks associated with hazardous voltage:
•   Use only the power supply provided by 3M and specified for the country of use.
•   Make sure that the WS Aware Workstation Monitor is properly grounded.
•   Do not simultaneously power the WS Aware Workstation Monitor with the power supply and the RJ45 data 

cable.

•   Do not plug the WS Aware Workstation Monitor into your 10/100BaseT Ethernet factory network!
•   Do not plug -3 versions into -5 interfaces and vice versa, this may cause irreversible damage to the WS 

Aware Workstation Monitor and FMS.

•   Do not use a longer screw to replace the supplied parts.
•   Use only a dry cloth when cleaning.

WARNING

To reduce the risks associated with environmental contamination:
•   Dispose of WS Aware Workstation Monitor and power supply in accordance with all applicable local and 

government regulations

CAUTION

To reduce the risk of damage to components or assemblies being handled:
•  WS Aware Workstation Monitor must be checked periodically to verify each test mode is functioning 

correctly.

•  Ensure proper operation of WS Aware Workstation Monitor by performing operational verification test as 

required.

•  Always properly ground your tools and dissipative mats to known good ground before connecting WS 

Aware Workstation Monitor for monitoring.

NOTICE

Summary of Contents for WS Aware CTC061

Page 1: ...User s Guide 3M WS Aware Workstation Monitor CTC061 CTC062 ...

Page 2: ...of 3M WS Aware Workstation Monitor 8 8 0 Remote Terminals 9 9 0 Wrist Strap Indication 10 10 0 Wrist Strap Output Signals 10 11 0 Monitoring of EMI on Tool Ground 11 12 0 Ground Indication 11 13 0 Output Signals 12 14 0 Modes of Operation 12 Stand Alone Operation Operation with Data Acquisition System DAS 15 0 Pinout of RJ45 Connector 13 16 0 Maintenance 14 Product Specifications 15 Product Brochu...

Page 3: ... informs the user when excess charge is present The systems must be installed as specified in this User s Guide in an indoor commercial industrial environment and have not been evaluated for other uses or locations If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Explanation of Signal Word Consequences WARNING Indicates...

Page 4: ...power the WS Aware Workstation Monitor with the power supply and the RJ45 data cable Do not plug the WS Aware Workstation Monitor into your 10 100BaseT Ethernet factory network Do not plug 3 versions into 5 interfaces and vice versa this may cause irreversible damage to the WS Aware Workstation Monitor and FMS Do not use a longer screw to replace the supplied parts Use only a dry cloth when cleani...

Page 5: ...ity at 40 C 3 0 Package Contents Check that the following items are included with the 3M WS Aware Workstation Monitor shipping box 1 ea WS Aware Workstation Monitor 2 ea Remote terminals for wrist straps 1 ea Ring terminal for grounding 1 ea 6x32 Screw 1 ea Power Supply Unit 2 ea 10 3 m mini DIN cables for connection between 3M WS Aware Workstation Monitor and remote terminals 1 ea User s Guide No...

Page 6: ...ption for four tool grounds is also available Red LEDs indicate that when wrist strap fails or when proximity sensor fails or when wrist strap is incorrectly plugged into the visitor s jack Green LEDs indicate that wrist straps are properly connected and worn Tool Ground LEDs all models Tri color LEDs that show green when ground impedance is within limits red when ground fails blinking yellow when...

Page 7: ...ative Surface 1 Tool Ground 3 Dissipative Surface 2 Tool Ground 4 Wrist Strap 1 OK Wrist Strap 2 OK Power LED Data Output Right Left Test Terminals Setup Button Power Jack Grounding Terminal Grounding Monitor Terminals Ground Enable Switches Expansion Programming Connector Remote Terminal 2 Connector Remote Terminal 1 Connector Buzzer ...

Page 8: ...4 Connect the WS Aware Workstation Monitor to its remote terminals using the supplied mini DIN cables Route the cables so that they are out of the way and do not interfere 7 5 Using 25 28 AWG wire connect the tools that you wish to monitor to the ground monitor terminals on the left side of the WS Aware Workstation Monitor Use a small screwdriver to press the orange levers when inserting or removi...

Page 9: ...e terminal has two 3 0 mm jacks one for the operator and another one for a visitor While both jacks provide grounding for the wrist straps only the operator s jack is monitored If the wrist strap is plugged into the visitor s jack and the operator s jack is empty an alarm will sound A green led on the front panel will light up when the wrist strap plugged into the remote terminal is working proper...

Page 10: ...p is worn properly but the red LED will blink Status Green LED Red LED Buzzer No wrist strap Off Off Off Wrist strap OK On Off Off Body voltage On Blinks Off Wrist strap Fail Off On Beeps 10 0 Wrist Strap Output Signals When connected to a Facility Monitoring System the 3M WS Aware Workstation Monitor provides output indicating each state of a wrist strap monitor This table shows the output curren...

Page 11: ...ame time Though presence of EMI does not create a failure alarm it is wise to investigate the cause and take measures to reduce EMI Please contact 3M for recommendations and for assistance in these matters 12 0 Ground Indication The following indication is available for each ground Status LED Buzzer Ground Disabled Off Off Ground OK Green Off Ground OK EMI Tool grounds only Yellow Off Ground Fail ...

Page 12: ...4 Good Good Failed Failed 3 25 13 Failed Good Failed Good 3 00 12 Good Failed Failed Good 2 75 11 Failed Failed Failed Good 2 50 10 Failed Good Good Failed 2 25 9 Good Failed Good Failed 2 00 8 Failed Failed Good Failed 1 75 7 Failed Good Failed Failed 1 50 6 Good Failed Failed Failed 1 25 5 Failed Failed Failed Failed 1 00 4 14 0 Modes of Operation The 3M WS Aware Workstation Monitor can work in ...

Page 13: ... interface options Relay RT model 4 20mA 3 model and LAN 5 model If a long data cable is used it is advisable to install ferrite clamp on chokes on both ends of the cable in order to reduce electromagnetic interference induced on cables Please contact a 3M Sales Representative or authorized distributor for proper selection of ferrite filters 15 0 Pinout of RJ45 Connector The WS Aware Workstation M...

Page 14: ...lug in the power Repairs and Servicing Do not attempt to repair the product yourself Contact a 3M Sales Representative or Authorized Dealer to request inspection and repair Replace power supply if damaged using only 3M supplied parts Other than replacement of remote jacks do not attempt to service the device There are no user serviceable parts Device Calibration Contact a 3M Sales Representative o...

Page 15: ... Tools 4 connections Connection Activation Tool Ground Alarm 10Ω default DIP switch enable disable Dissipative Ground Alarm 1GΩ default DIP switch enable disable Indicated Alarms Operator Resistance 35 Mohm Operator Body Voltage 2 5 Volts Mat Resistance 1000 Mohms Tool Impedance 1 20 Ohms Connectivity Analog Model 4 20mA Relay Model Logic level 0 5V Digital Model RS485 Ethernet Data Connector RJ45...

Page 16: ...ctor Fabrication Fiber Optics Flat Panel Fabrication Laser Diodes Electronic Assembly Industrial Robotics Medical etc Features Dual wrist strap monitor two remote terminal low test voltage on person body voltage monitoring tools monitoring mat monitoring connectivity to FMS compact etc Operator Grounding The WS Aware Workstation Monitor is available with the 3M Big Brother Operator Sensor that det...

Page 17: ... by third party suppliers to 3M This numerical reference should not be construed as a representation regarding the product s life or an extension of a product warranty In the event any product is proven not to conform with 3M s Regulatory Information Sheet then 3M s entire liability and buyer s exclusive remedy will be at 3M s option either i replacement of product with a conforming product or ii ...

Page 18: ...dicates that this hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in the SJ T11363 2006 X Indicates that this hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in the SJ T11363 2006 产品中有毒有害物质或元素的名称及含量 部件名称 有毒有害物质或元素 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 0603电容引脚 二极管焊接部 二极管电镀 印刷电...

Page 19: ...erference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense WEEE Statement The following information is only for EU members States The mark shown to the right is in compliance with Waste Electrical and Electronic Equipment Directive 2002 96 EC WEE...

Page 20: ...d in 3M s current publications or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon in writing by an authorized officer of 3M Warranty Limited Remedy Limited Liability This product will be free from defects in material and manufacture for one year from the time of purchase 3M MAKES NO OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO AN...

Page 21: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information 3M CTC061 5 243 WW CTC061 RT 242 WW CTC062 RT 242 WW CTC062 3 242 WW ...

Reviews: