![3M WS Aware CTC061 User Manual Download Page 15](http://html1.mh-extra.com/html/3m/ws-aware-ctc061/ws-aware-ctc061_user-manual_443114015.webp)
15
Specifications
Properties
Values
Wrist Strap Monitor
Wrist Strap Type
Dual, 3.0 mm plug
WS Connection to Ground
2 M
Ω
Number of Wrist Straps
2
Wrist Strap Voltage to Ground
Less than ~100 mVrms
Remote Terminals
2
Body Resistance Alarm Level
± 2.5V default
Indication/Alarm
LED, Buzzer
Ground Monitor
CTC061 Model
Tools: 2 connections
Mats: 2 connections
CTC062 Model
Tools: 4 connections
Connection Activation
Tool Ground Alarm
10
Ω
default, DIP-switch enable/disable
Dissipative Ground Alarm
1G
Ω
default, DIP-switch enable/disable
Indicated Alarms
Operator Resistance
35 Mohm
Operator Body Voltage
2.5 Volts
Mat Resistance
1000 Mohms
Tool Impedance
1-20 Ohms
Connectivity
Analog Model
4-20mA
Relay Model
Logic level: 0,5V
Digital Model
RS485/Ethernet
Data Connector
RJ45 jack
General
Power Supply
Universal 100 - 240VAC, 0.6A, 50-60Hz
Output: 12VDC, 1.5A
Dimension (approx.)
3.2” W x2.25” H x1.30” D
(81mm W x 57 mm H x 33 mm D)
Weight (approx.)
120g