42 • Ch. 4 Preventive Maintenance
SST Transport and Burster Mechanism Manual
7. Press the red RESET button, shown in Figure 4.6, once and then release it. This will reset
the CPU and allow it to read new DIP switch settings. LED lights D5 - D12 will light.
8. Press the red RESET button again. The stepper motor will turn on. If LED D7 lights, the
motor speed does not need to be adjusted. If the LED D7 does not light, you must adjust
the motor speed, as instructed in Adjusting the Motor Speed on the SST Transport, in
Chapter 6: Performing Field Repairs
.
9. Open DIP switch 7. Then open DIP switch 8.
10. Return the remaining DIP switches on the Switch Bank S1 to their original positions.
11. Press the red RESET button once to accept the new DIP switch settings.
Cleaning and Inspecting the Burster
Once you clean and inspect the SST Transport, you should do the same with the Burster. This will
help ensure that the Burster effectively bursts apart tickets. To clean and inspect your Single Infeed
or Dual Infeed Burster, complete the following steps.
Warning! Do not use fire, flame, or any other items which may spark while cleaning or
doing preventive maintenance on the SST Transport and/or Burster.
Figure 4.6
SST CPU Board
Red Reset
Button
LED D7
Switch Bank S1
Summary of Contents for SST
Page 1: ...SST Transport and Burster Mechanism Manual Version 1 3M Parking...
Page 2: ......
Page 10: ...vi List of Tables 75 0302 1450 8 Version 1 SST Transport and Burster Mechanism Manual...
Page 44: ...34 Ch 3 Burster Mechanism 75 0302 1450 8 Version 1 SST Transport and Burster Mechanism Manual...
Page 76: ...66 Ch 7 Troubleshooting 75 0302 1450 8 Version 1 SST Transport and Burster Mechanism Manual...
Page 89: ......