background image

ELSA 2000 Issue N

9

wearers must be referred to a properly 

equipped and trained service facility.
DO NOT perform maintenance tasks 

unless you have been trained and tasked 

to do so by a qualified, responsible expert.
It is a mandatory requirement that ELSA 

units are function-tested annually to 

ensure that the air supply is flowing 

freely from the cylinder into the hood. 

The Annual Flow test can be completed 

by the user in one of 2 ways, either using 

the ELSA flow meter or by activating the 

ELSA and timing that the whistle activates 

at the correct time. 
For 10 minute set – 10-11 minutes (starting 

from a 200 bar charge) 
For 15 minute set – 15-17 minutes (starting 

from a 200 bar charge) 
This test can be done, for example, when 

replacing the air in the cylinders

ROUTINE CHECKS

It is a mandatory requirement that all 

escape apparatus shall be checked at 

monthly intervals.
In addition, apparatus issued to wearers 

should be checked when issued and daily 

thereafter.
Apparatus held in ready-use lockers 

should be checked daily.
Apparatus held ready for use in a central 

store must be checked monthly.
Routine checks consist of the following:

Check that the contents gauge needle 

is in the green sector, showing that the 

cylinder is fully-charged.

Check that the bag is clean and 

undamaged.

Check that the anti-tamper tags are in 

place and unbroken.
Check that access to the bag is 

unobstructed.
Check that the quick fire strap and pin are 

in place.
Apparatus that fails any of these checks 

must be withdrawn from use and returned 

for workshop service or repair.

AFTER-USE CLEANING

CAUTION:
DO NOT immerse the hood or reducer/

cylinder valve. Fluid must not enter the 

inner mask.

Wipe the surface of the hood and bag 

using a clean lint-free cloth moistened in 

a solution of 

Distel

™ (available from 

Scott 

Safety

 in 1 litre and 5 litre containers) and 

warm water.
Allow the hood and bag to dry naturally 

away from direct heat and sunlight.
Disinfect the neck seal using a 

Distel

™ 

hygienic wipe, available from 

Scott Safety

.

Use an 

Exxene

™ de-misting wipe, available 

from 

Scott Safety

, to polish the visor.

CHARGING CYLINDERS

WARNING:
HP compressors and charging apparatus 

must only be used by trained operators.
Wear eye protection when working with 

HP air.
Air used to charge cylinders must 

conform to EN 12021:2014.

Summary of Contents for Scott Safety ELSA 2000

Page 1: ...1035070 N 08 2019 AS NZS 1716 2012 Lic BNP 540244 BSI BENCHMARK ELSA 2000 ...

Page 2: ......

Page 3: ... visibility and toxic fumes may add to your difficulties Prepare for that situation Learn the location of escape apparatus and how to gain access to it Learn to use the escape apparatus as detailed in these instructions Be aware of the protection limits provided by ELSA Exceeding these limits may cost you your life or result in injury Be fully aware of workplace hazards Become familiar with planne...

Page 4: ... Selfcontained open circuit compressed air breathing apparatus incorporating a hood for escape Requirements testing marking Conformity to Marine Equipment Directive MED 2014 90 EU yy Date of Manufacture CE European conformity These products are type approved and annually audited by either BSI Group The Netherlands B V Say Building John M Keynesplein 9 1066 EP Amsterdam The Netherlands Notified Bod...

Page 5: ...servicing schedule are contained in the Scott Safety ELSA Service Manual copies of which can only be obtained by registered holders of a current certificate Your Scott Safety distributor or Training and Technical Support Services will be pleased to provide training course details and quotes for service contracts Please see above for contact details STORAGE AND TRANSPORTATION The Device must be pro...

Page 6: ...inner mask which covers the wearer s nose and mouth minimises visor misting and carbon dioxide dead space Sprung metal strips hold the visor flat when in storage When in use form the hood to a shape that holds the inner mask against the wearer s face A sealed foam pad on the inner rear of the hood holds the hood in place when the wearer s head moves The spring loaded exhale valve helps maintain an...

Page 7: ...lling a webbing grab strap is held closed by Velcro strips An adjustable webbing neck strap supports the bag when in use A transparent panel is provided to enable the cylinder contents gauge to be checked without opening the bag A waist belt which prevents the bag swinging while in use is available as an option for all versions of the bag INSTRUCTIONS FOR USE Lift ELSA from the ready to use store ...

Page 8: ... LEAVE THE HAZARD AREA IMMEDIATELY When clear of the hazard area insert thumbs under the neck seal and remove the hood When the cylinder is almost empty the warning whistle sounds Beyond this point carbon dioxide within the hood will increase and the hood must be removed as soon as it is safe to do so Once the apparatus has been used it must be returned to be serviced and have the cylinder re char...

Page 9: ...or use in a central store must be checked monthly Routine checks consist of the following Check that the contents gauge needle is in the green sector showing that the cylinder is fully charged Check that the bag is clean and undamaged Check that the anti tamper tags are in place and unbroken Check that access to the bag is unobstructed Check that the quick fire strap and pin are in place Apparatus...

Page 10: ...he reducer cylinder valve clear of the water and immerse the cylinder vertically in water so that three quarters of the cylinder is covered Slowly open the compressor supply valve Charge cylinders at 40 L min 10 min cylinders should take approximately 10 minutes to charge and 15 min cylinders approximately 15 minutes then close the compressor supply valve When the cylinder has cooled check that it...

Page 11: ...ag flap and fit anti tamper tags WORKSHOP REPAIR AND ANNUAL SERVICING The apparatus must be returned for workshop servicing if The anti tamper tag is broken The contents gauge shows less than full The apparatus has been used A scheduled annual service is due please refer to the ELSA Service Manual Apparatus stored in a corrosive dusty or humid environment may require more frequent servicing Please...