CLEANING & STORING THE RESPIRATOR
40
To clean the mask-mounted regulator
1 Remove the breathing regulator from the facepiece by
engaging the
lock tab of the E-Z Flo+ regulator or the
latch on E-Z Flo C5 regulator
and rotating the
regulator one-quarter turn clockwise.
2 Using a sponge or soft cloth and the recommended
sanitizing or disinfecting cleaner, wipe the external
surfaces of the regulator.
3 Inspect the inside of the regulator assembly through
). If excessive dirt
or soil is present, forward the regulator assembly to
3M-trained authorized personnel for thorough
cleaning.
4
Engage the
lock tab or
latch. Close the
purge knob by turning it fully clockwise.
5
Using a spray bottle, apply the
sanitizing or
disinfecting cleaner to the surfaces of the regulator
opening and the immediate area around the opening
(see
). Be sure to cover the internal
components completely with the cleaning solution.
Figure 4-1 Cleaning the mask-mounted regulator
Follow the user instructions for the cleaner. A specific contact time may be required for sanitizing or disinfecting
before rinsing.
6 Set the regulator aside for the required contact time prior to rinsing.
The hypochlorite solution and the aqueous
solution of iodine require a 2-minute contact time.
7 Using gently running tap water or a spray bottle with drinking water, rinse the regulator inside and out.
8 Shake excess water out of regulator.
Completely air dry the regulator before use.
9 If the regulator was disconnected from the air supply for cleaning, reconnect and open the purge valve to remove
any moisture from regulator spray bar. Close the purge valve.
10 Perform a regulator check after each cleaning by following the steps listed in “
NOTE
When cleaning the regulator, do
not
use the following cleaning products:
•
Bleach stronger than a 3% solution in water
•
Solvents such as acetone, paint and lacquer thinner, benzene, or dry-cleaning fluid.
In addition, do
not
do the following:
•
“Dunk and slosh”
•
Autoclave or wash in an
unapproved
automatic washer
•
Use a vapor degreaser/polisher
TIP
To speed drying of the regulator, gently blow dry with clean, dry breathing air of 30 psig maximum. Do not
use shop air or any other air containing lubricants or moisture.
Regulator
opening
Wet all areas
within the circle
Auto air-saver/latch
P/N 595373-01
Rev
C
202004
Summary of Contents for SCOTT AIR-PAK X3 PRO
Page 2: ......
Page 8: ...CONTENTS vi P N 595373 01 Rev C 202004 ...
Page 20: ...INTRODUCTION 4 P N 595373 01 Rev C 202004 ...
Page 52: ...OPERATING THE RESPIRATOR 36 P N 595373 01 Rev C 202004 ...
Page 68: ...52 P N 595373 01 Rev C 202004 ...
Page 72: ...56 P N 595373 01 Rev C 202004 ...
Page 74: ...58 P N 595373 01 Rev C 202004 ...
Page 78: ...62 P N 595373 01 Rev C 202004 ...
Page 80: ...64 P N 595373 01 Rev C 202004 ...
Page 82: ...66 P N 595373 01 Rev C 202004 ...
Page 83: ......