3M IPC 2000
3M
Multimedia Projector MP8760
19
ENGLISH
6-3.
Lamp Life Indicator
The elapsed operating time of the lamp is displayed on the Info sub-menu. From the Main menu, select
INFO
to
display the lamp life. As long as the lamp indicator bar is green, the lamp is good. When the bar changes to red, the
lamp should be changed.
After changing the projection lamp, the lamp life indicator must be reset to zero.
To reset the lamp life indicator:
1.
Press the
Menu
button to display the main menu.
2.
Select the
Advanced Setup
sub-menu using the
Disc Pad
.
3.
Select
Reset lamp display
and press the
Enter
button.
4.
The following message will display: “
Really reset lamp life display? OK! / Cancel
”
5.
Using the
Disc Pad
, select
OK!
and press
Enter
to acknowledge the change.
6.
Press Menu to exit the menu system.
!
!
!
!
Note
To view the used/remaining lamp life:
(1)
Go to the Main Menu.
(2)
Select “Info”.
(3)
Press the Enter button.
6-4.
Cleaning the Projector
For best performance, keep your projector free of excess dust and surface dirt. Use a soft cloth to remove dust from
the projector housing. Use 3M
High Performance Cleaning Cloth to remove surface dirt and smudges from the
projection lens.
!
Caution
Always unplug the projector when cleaning. Take care that no liquids get inside
the projector. There are high voltage parts inside the cabinet that may
cause
electric shock
.
Figure 6-3. High Performance Cleaning Cloth