8.  When stored in accordance with temperature and humidity conditions specified below, the product may be used until the “use by” date specified 

on the packaging.

Storage Conditions and Shelf Life

Before use, store respirators in the original packaging, away from contaminated areas, dust, sunlight, extreme temperatures, excessive moisture and 

damaging chemicals. When stored in accordance with temperature and humidity conditions specified below, the product may be used until the “use 

by” date specified on packaging. Always inspect product and conduct a user seal check before use as specified in these 

User Instructions

If you 

cannot achieve a proper seal, do not enter the contaminated area. See your supervisor.

End of Shelf Life  

Use respirators before the “use by” date specified on packaging

+86˚F

+30˚C

-4˚F

-20˚C

Storage Temperature Range  

-20°C (-4°F) to +30°C (+86°F)

<80%

Storage Maximum Relative Humidity 

<80% RH

Time Use Limitation

1.  If respirator becomes damaged, soiled, or breathing becomes difficult, leave the contaminated area and dispose of the respirator.
2.  If used in environments containing only oil aerosols, dispose of respirator after 40 hours of use or 30 days, whichever is first.

FOR MORE INFORMATION

In United States, contact:

Website: www.3m.com/workersafety

Technical Assistance: 1-800-243-4630

For other 3M products:

1-800-3M-HELPS or 1-651-737-6501

RENSEIGNEMENTS SUPPLÉMENTAIRES

Aux États-Unis :

Internet : www.3m.com/workersafety

Assistance technique : 1 800 243-4630

Autres produits 3M :

1 800 364-3577 ou 1 651 737-6501

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Fitting Instructions

Must be followed each time respirator is worn.

1.  Cup the respirator in your hand, with the nosepiece at your fingertips, allowing the headbands to hang freely below your hand (Fig. 1).
2.  Position the respirator under your chin with the nosepiece up. Pull the top strap over your head resting it high at the top back of your head. Pull the 

bottom strap over your head and position it around the neck below the ears (Fig. 2).

3.  Place your fingertips from both hands at the top of the metal nosepiece. Using two hands, mold the nose area to the shape of your nose by pushing 

inward while moving your fingertips down both sides of the nosepiece (Fig. 3).

 

W

 Pinching the nosepiece using one hand may result in improper fit and less effective respirator performance. Use two hands.

4.  Perform a User Seal Check prior to each wearing. To check fit, place both hands completely over the respirator and inhale sharply (Fig. 4). Be 

careful not to disturb the position of the respirator. A negative pressure should be felt inside the respirator. If air leaks around nose, readjust the 

nosepiece as described in step 3. If air leaks at the respirator edges, work the straps back along the sides of your head. 

If you CANNOT achieve a 

proper fit, DO NOT enter the contaminated area. See your supervisor.

Summary of Contents for P95

Page 1: ...vel acid gas refers to concentrations not exceeding OSHA PEL or applicable government occupational exposure limits whichever is lower Recommandé par 3M contre les concentrations nuisibles de gaz acides Par concentrations nuisibles de gaz acides on entend les concentrations inférieures à la limite d exposition admissible de l Occupational Safety and Health Administration OSHA des États Unis É U ou ...

Page 2: ...rotection program must be implemented meeting all the requirements of OSHA 29 CFR 1910 134 such as training and fit testing and applicable OSHA substance specific standards In Canada CSA standard Z94 4 93 requirements must be met and or requirements of the applicable jurisdiction as appropriate 3 The particles which can be dangerous to your health include those so small that you cannot see them 4 ...

Page 3: ...3M products 1 800 3M HELPS or 1 651 737 6501 RENSEIGNEMENTS SUPPLÉMENTAIRES Aux États Unis Internet www 3m com workersafety Assistance technique 1 800 243 4630 Autres produits 3M 1 800 364 3577 ou 1 651 737 6501 Fig 1 Fig 2 Fig 3 Fig 4 Fitting Instructions Must be followed each time respirator is worn 1 Cup the respirator in your hand with the nosepiece at your fingertips allowing the headbands to...

Page 4: ...ed by regulatory standards J Failure to properly use and maintain this product could result in injury or death M All approved respirators shall be selected fitted used and maintained in accordance with MSHA OSHA and other applicable regulations N Never substitute modify add or omit parts Use only exact replacement parts in the configuration as specified by the manufacturer O Refer to users instruc...

Page 5: ...ules biologiques en suspension dans l air p ex moisissures bacille du charbon bacille de Koch etc mais il n élimine pas le risque de contracter une infection ou une maladie L OSHA et d autres organismes gouvernementaux n ont pas établi de limites d exposition sécuritaires pour ces contaminants Directives d utilisation 1 Tout manquement aux directives et aux restrictions relatives à l utilisation d...

Page 6: ...irectives d utilisation précisées Si l on ne peut obtenir un ajustement parfaitement étanche ne pas pénétrer dans la zone contaminée Consulter son superviseur Fin de la durée de conservation Utiliser le respirateur avant la date de péremption indiquée sur l emballage 86 F 30 C 4 F 20 C Plage de températures d entreposage 20 C à 30 C 4 F à 86 F 80 Humidité relative maximale pour l entreposage 80 Du...

Page 7: ...FILTRATION FACIALE COMPOSANTS DES RESPIRATEURS 3M St Paul Minnesota USA 1 800 243 4630 A Ne pas utiliser dans les endroits où le taux d oxygène est inférieur à 19 5 B Ne pas utiliser lorsque l atmosphère présente un danger immédiat pour la vie ou pour la santé C Do not exceed maximum use concentrations established by regulatory standards J L utilisation et l entretien inadéquats de ce respirateur ...

Page 8: ... tiempo de exposición se puede reducir su efectividad y causar enfermedades o la muerte 2 Antes del uso ocupacional de este respirador se debe poner en práctica un programa de protección respiratoria estipulado por escrito que cumpla con todos los requisitos del Código de Reglamentos Federales 29 1910 134 de OSHA como por ejemplo aquellos que se refieren a la capacitación y pruebas de ajuste y las...

Page 9: ...o no ingrese al área contaminada Consulte a su supervisor Fin de la vida útil Use los respiradores antes de la fecha de vencimiento especificada en el empaque 86 F 30 C 4 F 20 C Rango de temperatura de almacenamiento Entre 20 C 4 F y 30 C 86 F 80 Humedad relativa máxima de almacenamiento 80 de humedad relativa HR Limitación del tiempo de uso 1 Si el respirador se daña ensucia o se hace difícil res...

Page 10: ... natural Aprobado por NIOSH N95 95 mínimo de eficiencia de filtración contra aerosoles sólidos y líquidos que no contienen aceite THIS RESPIRATOR IS APPROVED ONLY IN THE FOLLOWING CONFIGURATIONS FILTERING FACEPIECE TC PROTECTION1 8271 8576 8577 CAUTIONS AND LIMITATIONS2 84A 1166 P95 X X X ABCJMNOP 1 PROTECTION 2 CAUTIONS AND LIMITATIONS A Not for use in atmospheres containing less than 19 5 percen...

Page 11: ... 因職業需要在使用此呼吸防護具之前 必須擬定一個書面的呼吸保護計劃符合OSHA 29 CFR 1910 134的要求 如訓練和 密合度測試以及適用的 OSHA 指定標準 在加拿大 必須符合CSA Z94 4 93標準和適用的司法要求 3 可能對你的健康有害的粒狀物包括那些小到你看不到的顆粒 4 如果發生眩暈 刺激感或其他不適 立即離開污染區域並聯繫主管 5 不使用時 將呼吸防護具遠離污染區域 6 在每次使用前檢查呼吸防護具 確保其處於良好的運行狀態 檢查呼吸防護具的所有部位是否有損壞跡象 包括兩條頭 帶 部件接合點和鼻樑夾 觀察到損壞或零件缺失時 該呼吸防護具應該立即拋棄 在每次使用之前要檢查防護具 確保 呼吸區域沒有破孔 除了縫釘周圍的穿刺以外沒有其他損壞 在縫合釘周圍因拉伸引起濾材穿孔的擴大被視為損壞 如果 損壞 立即更換呼吸防護具 裝訂穿孔不影響NIOSH的批准 7 按照適用規定處理...

Page 12: ...棄呼吸防護具 2 如果僅在含有油性氣溶膠的環境中使用 請在使用 40 小時或 30 天後拋棄呼吸防護具 以較低者為準 Fig 1 Fig 2 Fig 3 Fig 4 配戴說明 每次佩戴口罩時必須遵守 1 將口罩放在手中 將鼻樑夾放在指尖處 讓頭帶自由懸掛在手下 圖1 2 將口罩置於下巴下方 鼻樑夾向上 將頂部的頭帶拉到頭頂並將底部頭帶拉到耳朵下方的頸部位置 圖2 3 將雙手食指及中指指尖放置在鼻樑夾頂部 順著鼻子的形狀向兩側按壓使口罩與鼻子的接觸部位密合 圖3 W 使用一隻手按壓鼻樑夾可能會導致不正確的密合度使得口罩之呼吸防護效能較差 使用雙手 4 每次佩戴口罩時須執行密合度檢點 將雙手在不影響口罩佩戴位置下蓋住口罩外側然後吸氣和呼氣 圖4 如果空氣在 鼻子周圍發生洩漏 請重新如第3步所述調整口罩之佩 戴 如果空氣在口罩邊緣發生洩漏 重新調整頭帶位置 如果調整 後狀況無法改善 不要進入作業...

Page 13: ...jury or death M All approved respirators shall be selected fitted used and maintained in accordance with MSHA OSHA and other applicable regulations N Never substitute modify add or omit parts Use only exact replacement parts in the configuration as specified by the manufacturer O Refer to users instructions and or maintenance manuals for information on use and maintenance of these respirators P NI...