 Remove old unit

Label Wires to Old Unit

Mount the 3M-10

Separate front from back of unit. Grasp the front of the 

unit and the back of the unit and  pull apart. The
thermostat body away from the base.

Hold the base against the wall, with the wires coming 

through the opening below the terminal block. 

Position the base for best appearance 

Attach the base to the wall with the two 

screws provided.

If you are mounting the base to sheet 

rock or if you are using the old 
mounting holes, use the plastic 
anchors provided. 
Drill a 3/16-in.(4.8mm) hole 
for the insert at each screw 
location, then mount the base.

PG

 3

PG

 4

Terminals

• Switch electricity to the furnace and air conditioner OFF; 
then proceed with the following steps.
• Remove cover from old thermostat. Most are snap-on types and simply pull 
off. Some have locking screws on the side or front. These must be loosened.
• Note the letters printed near the terminals. 
• Carefully attach labels (enclosed) to each wire. Label the wires one at a 
time.

You must have all the wires labeled before you proceed.

Remove the wires from the terminals of the old thermostat.
•Make sure the wires 

do not fall back inside

 the wall. 

•Wind them around a pencil to 

keep them from falling

.

•Remove the old thermostat from the wall. Fill wall 
opening with fiber glass insulation to prevent drafts.

Caution

DO NOT REMOVE WIRES FROM OLD THERMOSTAT UNTIL YOU HAVE
CAREFULLY LABELED THEM, WITH LABELS PROVIDED.
THERE IS NO STANDARD COLOR CODE FOR THESE WIRES.

Summary of Contents for Filtrete 3M-10

Page 1: ...ENGLISH Install Guide 3M 10...

Page 2: ...t On replacement installations mount the new thermostat in place of the old one if possible Locate the thermostat on an inside wall about 5 ft 1 5m above the floor and in a room that is used often Do...

Page 3: ...ricity to the furnace and air conditioner OFF then proceed with the following steps Remove cover from old thermostat Most are snap on types and simply pull off Some have locking screws on the side or...

Page 4: ...tteries The 3M 10 requires batteries to operate your system Switch MODE switch to OFF and the FAN switch to AUTO Insert 2 AA alkaline batteries according to the polarity noted in the compartment NOTE...

Page 5: ...ep wiring diagram you should use This may require you to find the other end connection for each wire on your heating or air conditioning equipment and read the label there If you have a Zoned Heating...

Page 6: ...switch to the ON position Verify air is blowing from vents After test return to Fan switch to AUTO and Mode to HEAT or COOL To check HEAT mode Set the mode switch to HEAT Set the fan switch AUTO Adju...

Page 7: ...the Heater Power STEP 2 Connect the W wire to the W terminal on the thermostat This connects the heater control line to the thermostat STEP 3 Connect the G wire to the G terminal on the thermostat Th...

Page 8: ...STEP 3 Connect the RH wire to the RH terminal on the thermostat This connects to the Heater Power STEP 4 Connect the RC wire to the RC terminal on the thermostat This connects to the Cooling Power ST...

Page 9: ...y Heat NOTE Wires marked with the dotted line are optional NOTE Wires marked with the dotted line are optional O or B Single Stage HEAT PUMP Change Over G O or B R C FAN Y Comp 24VAC Power jumper wire...

Page 10: ...G 18 PG 17 STEP 1 Connect the G wire to the G terminal on the thermostat This connects the Fan STEP 2 Add a jumper wire between W and Y STEP 3 Connect the Y wire to the Y terminal on the thermostat Th...

Reviews: