3M™ MicroTouch™ Controller SX112 Reference Guide
33
3M Touch Systems, Inc. Proprietary Information
±
8 kV Contact Discharge
*
- 1 “touch” allowed
Compliant with Class 2 operation per section 9 of IEC 61000-4-2
±
22 kV Air Discharge
*
– Normal Operation – No false touches
Compliant with Class 1 operation per section 9 of IEC 61000-4-2
* ESD discharges to the tip and tapered end of the pen when connected to an SX112 controller
Operating and Storage Environmental Conditions
Operating Temperature Range
- 15
°
C to +70
°
C
Operating Humidity Range
< 36° C 0-90% RH
(All Humidity is Non-Condensing)
≥
36
°
C see Figure below
Storage Temperature Range
- 30
°
C to +70
°
C
Storage Humidity Range
< 36°C 0-90% RH
(All Humidity is Non-Condensing)
≥
36
°
C see Figure below
Agency Compliance
UL Recognized Component (UL File No. E155649)
Reliability – Mean Time To Failure
4 Million Hours MTTF -
Calculated per Mil Handbook 217-F1 @ 35°C
Storage and Operating Temperature with Humidity Conditions