![3M Dynatel 2250M Series Operator'S Manual Download Page 91](http://html1.mh-extra.com/html/3m/dynatel-2250m-series/dynatel-2250m-series_operators-manual_442590091.webp)
Care & Maintenance
Section 4
Page 82
R
B
G
Y
3.
CHECK OPENS PERFORMANCE
3.1
To check OPENS performance, use the Cable Self
Test Circuit included with your set, shown above.
Attach the red lead to terminal “R” and the black lead to
terminal “B.” Press the
OPENS
key. The results in feet or
meters should be in the ranges shown in the table below.
Note:
The test set circuits are more accurate than the Cable Self
Test Circuit, so the limits in the table below are wider than in the
Specification section.
Opens Self Test Limits in feet/meters
Capaci-
tance
Air
Core
Jelly-
Filled
2-Pair 5-Pair
Drop
Drop
MAX
MIN
MIN
MIN
MIN
MAX
MAX
MAX
Normal
Tip
or Ring
Normal
Mutual
Special
Tip
or Ring
Special
Mutual
Cable Type:
9.35 nF
.01065 uF
9.35 nF
8.75 nF
.01125 uF
395/120
450/137
595/181
680/207
370/113
475/145
560/171
715/218
425/130
330/101
595/181
400/122
350/107
320/98 330/101
375/114
365/111
595/181 595/181
300/91
310/94
385/117 395/120
8.75 nF
.01125 uF
680/207 680/207 680/207
560/171
715/218
560/171
715/218
560/171
715/218
.01065 uF