![3M Dynatel 2220M-C3W-CPLR Operator'S Manual Download Page 22](http://html1.mh-extra.com/html/3m/dynatel-2220m-c3w-cplr/dynatel-2220m-c3w-cplr_operators-manual_442853022.webp)
22
78-9000-0021-3-D
November 2016
Sonde Locating Screen
➊
➋
➌
➍
➎
➏
➐
1. Speaker Icon
– Indicates audio level
2. Bar graph
– Graphical representation of received signal
3. Antennae Icon
– Indicates Special (Single) Peak mode
4. Selected Sonde Frequency
– Toggles through activated sonde
frequencies (512, 640, or 33 k)
5. Sonde Icon
– Indicates sonde mode vs . line locating
6. Battery Icon
– Indicates battery level of receiver
7. Signal Level
– Numerical reading of received signal (dB)
Pin-Pointing the Sonde
Note: The receiver handle must be oriented perpendicular to the sonde. The
cross bar of the receiver must be in line with the sonde (the opposite
of line locating).