background image

3M

 

Water Filtration Products

Table of Contents

Safety Information .......................................................................................................................................2

Warning Statements ....................................................................................................................................2

Caution/Important Notes ..............................................................................................................................3

Inlet and Outlet Connections ........................................................................................................................3  

Product Dimensions ....................................................................................................................................4

How to Use “Push-in” Connectors ................................................................................................................5

How to Use “Inlet/Outlet” Fitting/Retention Clip ............................................................................................5

Equipment Installation .................................................................................................................................5

Equipment Start-up Procedure  ....................................................................................................................6

Cartridge Change-out Procedure ..................................................................................................................7

Troubleshooting ...........................................................................................................................................7

Parts Listing ................................................................................................................................................8

Limited Warranty ........................................................................................................................................10

SAFETY INFORMATION

Read, understand, and follow all safety information contained in these instructions prior to installation.  Retain 
these instructions for future reference.

Intended Use:

 

The manifolds and water filtration systems are intended for use in filtering potable water in the foodservice industry 
and have not been evaluated for other uses. These systems are installed at the point of use and must be installed as 
specified in the installation instructions. 

EXPLANATION OF SIGNAL WORD CONSEQUENCES

WARNING

Indicates a potentially hazardous situation, which, if not avoided, could result in death or 
serious injury and/or property damage.

CAUTION

       

Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate 
injury and/or property damage.

CAUTION

Indicates a potentially hazardous situation, which, if not avoided, may result in property damage.

WARNING

To reduce the risk associated with choking:
 

 t

Do not

 allow children under 3 years of age to have access to small parts during the installation of this product.

To reduce the risk associated with the ingestion of contaminants:
 

t

Do not 

use with water that is microbiologically unsafe or of unknown quality without adequate disinfection 

      before or after the system.  Systems certified for cyst reduction may be used on disinfected water that

may contain filterable cysts. EPA Establishment #10350-MN-007 and/or # 070595-CT-001.

To reduce the risk associated with hazardous voltage due to an installer drilling through existing electric 
wiring or water pipes in the area of installation:

 t

Do not

 install near electric wiring or piping which may be in path of a drilling tool when selecting the  

      position to mount the filter bracket.

To reduce the risk of physical injury:

 t%FQSFTTVSJ[FTZTUFNBTTIPXOJONBOVBMQSJPSUPDBSUSJEHFSFNPWBM

To reduce the risk associated with back strain:

 t'PMMPXTBGFMJGUJOHQSPDFEVSFT

2

Summary of Contents for Dual Manifold Water Filtration Systems

Page 1: ...Installer Please leave this manual with owner operator Dual Triple Manifold Water Filtration Systems Instruction Manual High Flow Series Water Filtration Systems 3MTM Water Filtration Products ...

Page 2: ...ndicates a potentially hazardous situation which if not avoided may result in minor or moderate injury and or property damage CAUTION Indicates a potentially hazardous situation which if not avoided may result in property damage WARNING To reduce the risk associated with choking t Do not allow children under 3 years of age to have access to small parts during the installation of this product To re...

Page 3: ...is condition t Do not use a torch or other high temperature sources near filter system cartridges plastic fittings or plastic plumbing t 0O QMBTUJD mUUJOHT OFWFS VTF QJQF TFBMBOU PS QJQF EPQF 6TF 15 UISFBE UBQF only pipe dope properties may deteriorate plastic t 5BLF DBSF XIFO VTJOH QMJFST PS QJQF XSFODIFT UP UJHIUFO QMBTUJD mUUJOHT BT EBNBHF NBZ PDDVS JG PWFSUJHIUening occurs t Do not install in di...

Page 4: ...tridge 24 1 16 63 66 cm HF6X Series Cartridge 18 1 16 45 9 cm HF4X Series Cartridge 15 1 16 38 3 cm Triple Manifold Filtration System Product Dimensions 22 7 8 in 58 10 cm 13 65 cm 5 3 8 in To Remove Cartridge 3 in 7 62 cm Minimum HF9X Series Cartridge 24 1 16 63 66 cm HF6X Series Cartridge 18 1 16 45 9 cm HF4X Series Cartridge 15 1 16 38 3 cm ...

Page 5: ...aces with windows in the manifold head near each connection port clip is flexible and easily assembled following these instruction and illustrations 1 Insert fitting into manifold 2 With fitting inserted into manifold port snap clip into place beginning at the bottom window 3 Push center tab into center window 4 Finally push top tab into top window How to Use the Inlet Outlet Fitting and Retention Cl...

Page 6: ...rear and outlet right front fittings to the manifold The inlet kit includes the fitting a ball valve and a nipple The outlet is a fitting only The instructions for the retention clips are on page 4 6 Remove the sanitary caps from the cartridges and apply a light coat of water or food grade lubricant to the o rings on each of the cartridges 7 One at a time align the tabs of the cartridge with the slot...

Page 7: ... small amount of water will drain from manifold as cartridge is removed 6 Remove sanitary cap from new cartridge Install cartridge with a quarter turn to the right until cartridge comes to a complete stop IMPORTANT NOTE Cartridges are keyed to fit proper location only 7 Slowly turn the valve on the manifold to the ON position and check for leaks 8 Flush per the performance data sheet System is now ...

Page 8: ...et outlet fittings 6 63597320 o ring 1 Seal inlet outlet fittings 7 6220505 Inlet fitting kit 1 Inlet fitting with ball valve 8 6220506 Outlet fitting kit 2 Outlet fitting 9 60 235380 x ball valve 1 Inlet water shut off 10 85005 49 Pressure Gauge optional 1 Monitor inlet water pressure 11 Inquire Retainer Kit 1 Secure Cartridges Double Manifold Replacement Parts Listing Per part number not per system or...

Page 9: ...20 o ring 1 Seal inlet outlet fittings 7 6220505 Inlet fitting kit left rear 1 Inlet fitting with ball valve 9 6220507 Outlet fitting kit right front 1 outlet fitting 10 60 235380 Pressure Gauge optional 1 Inlet water shut off 11 85005 49 Pressure gauge Optional 1 Monitor inlet water pressure 12 Inquire Retainer Kit 1 Secure cartridges Triple Manifold Replacement Parts Listing Per part number not per s...

Page 10: ...during the warranty period 3M Purification Inc at it s option will replace the Product or refund your Product purchase price This warranty does not cover labor The remedy stated in this paragraph is Customer s sole remedy and 3M Purification Inc s exclusive obligation This warranty gives you specific legal rights and you may have other rights which may vary from state to state or country to country F...

Page 11: ...11 ...

Page 12: ...mpany All rights reserved 34 8712 8017 7 Please Recycle Printed in U S A 3M Purification Inc 400 Research Parkway Meriden CT 06450 USA Toll Free 866 990 9785 Worldwide 203 237 5541 Fax 203 238 8701 www 3Mfoodservice com www 3Mpurification com 12 ...

Reviews: