background image

Read, understand, and follow all safety information contained in these instructions prior to installation and use of the 3M

 

Water Filtration Products Dual Inlet Dual Flow Manifold System DIDF260-CL. Retain these instructions for future reference.
Intended use:

The Dual Inlet Dual Flow Manifold System DIDF260-CL is intended for use in filtering potable water for foodservice equipment and has not 
been evaluated for other uses. The system is installed indoors, and must be installed by a qualified professional installer according to these 
installation instructions.

 

 

SAFETY INFORMATION

EXPLANATION OF SIGNAL WORD CONSEQUENCES

WARNING

Indicates a potentially hazardous situation, which, if not avoided, could result in 
death or serious injury and/or property damage.

CAUTION

Indicates a potentially hazardous situation which, if not avoided, may result in 
minor or moderate injury and/or property damage.

 CAUTION

Indicates a potentially hazardous situation, which, if not avoided, may result in 
property damage.

WARNING

To reduce the risk associated with the ingestion of contaminants:

• 

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

 

Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. EPA Establishment #070595-CT-001

To reduce the risk associated with choking:

• 

Do not

 allow children under 3 years of age to have access to small parts during the installation of this product.

To reduce the risk associated with hazardous voltage due to an installer drilling through existing electric or water pipes in the area of installation:

• 

Do not 

install near electric wiring or piping which may be in path of a drilling tool when selecting the position to mount the system bracket.

To reduce the risk of physical injury:

•  Depressurize system as shown in manual prior to cartridge removal.

To reduce the risk associated with back strain: 

•  Follow safe lifting procedures.

1

Summary of Contents for DIDF260-CL

Page 1: ...ve this manual with owner operator Owner Operator Please retain for operation and future instructions 3M Water Filtration Products Installation and Operation Instructions for Dual Inlet Dual Flow Manifold System DIDF260 CL ...

Page 2: ...NOTES ...

Page 3: ...damage CAUTION Indicates a potentially hazardous situation which if not avoided may result in property damage WARNING To reduce the risk associated with the ingestion of contaminants Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected water that may cont...

Page 4: ...ster Contact a plumbing professional if you are uncertain how to check for this condition Any non metallic fittings used in the installations must be of adequate rating for the line pressure Where a backflow prevention device is installed on a water system a device for controlling pressure due to thermal expansion must be installed Do not use a torch or other high temperature sources near system c...

Page 5: ...ridge is keyed such that it will not fit properly if installed in either of the other manifold heads The media in this cartridge is a pleated nylon membrane with a time released scale inhibitor It filters the water going to the ice machine The water for the ice machine exits the manifold on the left side front connection labeled Outlet Ice The two cartridges to the right of the ice cartridge blue ...

Page 6: ... leak from its push in connector Cut off at least 1 4 0 6 cm from the end Reattach the tubing to its push in connector Confirm connection is leak free How to Use the Inlet Outlet Fitting Retention Clips This product is outfitted with inlet outlet fittings The fittings can be attached or removed from the system without tools Retention clips are semi circular in shape with three internal tabs bottom...

Page 7: ... 1 4 3 8 6 10 mm of each fastener to protrude from the surface Install the manifold onto the fasteners Tighten the fasteners 5 Install inlet fitting kits for the ice water inlet and the beverage water inlet left and right rear respectively Attach retention clips to fittings Detailed instructions for the retention clips can be found on page 4 6 Install outlet fitting kits 7 Remove the sanitary cap ...

Page 8: ...R5 Cartridge yellow label Replacement 1 Relieve pressure in the ice line by opening valve downstream 2 Push and hold yellow tab to release cartridge locking mechanism while simultaneously rotating cartridge to the left 3 Using both hands and holding the cartridge from the bottom rotate the cartridge a quarter turn to the left and gently pull down NOTE A small amount of water will drain from manifo...

Page 9: ...lve 5 Flush system in accordance with the cartridge Performance Data Sheet Troubleshooting Problem Potential Cause s Suggested Solution No water flow through system Inlet valve closed Cartridges clogged Check shut off valve position Replace cartridges Not enough water to the downstream application s Low incoming water pressure Cartridges clogged Check source Replace cartridges Short filter life Te...

Page 10: ...Monitor inlet water pressure 3b 8500556 Outlet Pressure Gauge 1 Monitor outlet water pressure 4 50 91401 Fitting Retention Clip O Ring not shown 1 Retain seal inlet outlet fittings 5 6225008 Inlet Fitting Kit 1 Fitting 6 6225006 Outlet Fitting kit 1 Fitting Per part number not per system or assembly Replacement Parts Listing TOP VIEW FRONT VIEW 2a 2b 2b Fitting Kit 7 4 4 4 4 4 4 4 4 3a 3b 3b 4 5 5...

Page 11: ...roduct fails to satisfy this Limited Warranty during the warranty period 3M Purification Inc will replace the Product or refund your Product purchase price This warranty does not cover labor The remedy stated in this paragraph is Customer s sole remedy and 3M Purification Inc s exclusive obligation This warranty gives you specific legal rights and you may have other rights which may vary from stat...

Page 12: ...an affect the performance of the Product s in a particular application some of which are uniquely within your knowledge and control INFORMATION IS SUPPLIED UPON THE CONDITION THAT THE PERSONS RECEIVING THE SAME WILL MAKE THEIR OWN DETERMINATION AS TO ITS SUITABILITY FOR THEIR USE IN NO EVENT WILL 3M PURIFICATION INC BE RESPONSIBLE FOR DAMAGES OF ANY NATURE WHATSOEVER RESULTING FROM THE USE OF OR R...