background image

9

8.5 Testing for Proper Operation

8.51   To make sure that your ionizing

air gun is working properly,
check the balance and discharge
levels. The performance of the
unit should be measured
periodically using a charged plate
monitor, such as the 3M™ 711
Charge Analyzer or the 3M™
713 Handheld Ionizer Tester. 

8.52   Calibration should be performed

in accordance with the ESD
Association ionization standard
ANSI/ESD-S3.1, or the IEC
standard 61340-5-1, Figure
A.5.14. At a line pressure of 30
psi (2 bars), discharge of 
+/- 1000 volts to +/- 100 volts
should require less than 1 second
at a distance of 6 inches (15 cm)
and balance should be /-
30 volts of zero.

9.0 Specifications for 3M™ 980/980E Ionized Air Gun

9.1 General

Audible Noise 

73dBA @ 1 meter, 30 psi (2 bars) pressure to air gun 

Conducted EMI 

29 dB

µ

, average level, from 100 kHz-1.1MHZ

Ozone 

<0.005 ppm (24 hour accumulation) 

Certifications 

UL and C-UL for 980
CE for 980E

9.2 Hand Unit

Construction Static-dissipative 

polycarbonate

Ion Emission 

Steady-state DC

Emitter Points 

Tungsten alloy

Ion Indicator 

Green LED

Air Hose 

7' (2.1m) length, 3/8" (0.96 cm) outside diameter
of static-dissipative polyurethane

Gun Hanger 

#302 stainless steel

Dimensions 

8.0" L x 3.0" W x 1.0" D (20.3 cm L x 7.6 cm W x 2.5 cm D )

Weight 

12.0 oz. (341 g) with 7' (2.1 m) air hose

Summary of Contents for 980

Page 1: ...3 980 980E Ionized Air Gun Instruction Manual...

Page 2: ...dex Section Page 1 General Description 3 2 Performance 3 3 Power Requirements 3 4 Air Supply Requirements 3 5 Installation 4 6 Assembling the Components 5 7 Operation 6 8 Maintenance 7 9 Specification...

Page 3: ...and ESD safe An extremely low EMI level minimizes any chance that the 980 might interfere with other electronic equipment or operations 2 0 Performance The 980 reduces a static charge of 1000 V to 100...

Page 4: ...groove inside the console Mount the console using the instructions below 5 2 Permanent Mounting Attach the supplied mounting plate to the threaded holes on the back of the console using the supplied s...

Page 5: ...the console until it latches with a click The fitting fits only in the correct orientation The small plastic fitting on the end of the filter must align with the metal guide coupling in the console Yo...

Page 6: ...inating surfaces Please refer to the pertinent regulations concerning maximum air pressure on hand held air blow devices in order to determine a safe operating pressure WARNING Use of this equipment w...

Page 7: ...Extremely dirty emitter points will increase the time needed to discharge static 8 2 Replacing the Air Filter 3M recommends changing the filter every three months or when it begins to look dirty Repl...

Page 8: ...the inside of the gun barrel 8 35 Align the blunt prongs of the emitters with the holes in the barrel and set the clip into place 8 36 Press the clip all the way in using the tip of a screwdriver It...

Page 9: ...require less than 1 second at a distance of 6 inches 15 cm and balance should be within 30 volts of zero 9 0 Specifications for 3M 980 980E Ionized Air Gun 9 1 General Audible Noise 73dBA 1 meter 30 p...

Page 10: ...21 6 cm L x 7 6 cm W x 4 1 cm D Weight 11 5 oz 326 g 9 4 Wall Transformer Input Power 980 AC 120 V 960X 980X 50 60 Hz 32 watts 980 AC 230 V 980E X 50 60 Hz 32 watts Output Power AC 24 V 1 0 amperes Ca...

Page 11: ...bility This product will be free from defects in material and manufacture as of the date of purchase 3M MAKES NO OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY O...

Reviews: