![background image](http://html1.mh-extra.com/html/3m/980/980_instruction-manual_3241945008.webp)
8
8.31 Insert the tip of a screwdriver
into the slot on the gun barrel.
See Figure 4.
8.32 Using the screwdriver as a lever,
loosen the old clip, grasp it
between your thumb and
forefinger, and detach it from the
gun. The emitter points are very
sharp; touch only the plastic lip,
and handle it carefully. To avoid
damaging the points, do not
touch them with hard objects
such as a screwdriver.
8.33 To insert the new emitter points,
hold the gun with the barrel
pointing up.
8.34 Grasp the new clip between
your thumb and forefinger, and
align it so the curved edges
match the curve of the inside of
the gun barrel.
8.35 Align the blunt prongs of the
emitters with the holes in the
barrel and set the clip into place.
8.36 Press the clip all the way in
using the tip of a screwdriver. It
should fit snugly between the
raised rim of the barrel and the
raised rim of the air nozzle. If
the clip overlaps the air nozzle,
it is installed backward.
8.4 Replacement & Optional Parts
Table 1 lists the replacement parts and
optional parts available for the 3M™
980/980E Ionized Air Gun.
Part Part
#
Status
120 Volt AC Wall Transformer
960X/980X
Replacement
230 Volt AC Wall Transformer
980E-X
Replacement
Air Filter 3-Pack
980-F
Replacement
Mounting Stand
980-G
Optional
Plastic Gun Tip
980-T
Replacement
Foot Switch
980-S
Optional
Table 1: Replacement and optional parts
Fig. 4