
9
2.14
Check for buffer clamp. If the clamp is partially actuated, remove the connector and repeat at Section
2.12
2.15
Hold the cable holder by both sides. SLOWLY slide
back the connector to insert fiber into the connector.
Caution: Do NOT TOUCH CABLE until splice is actuated
at Section 2.17.
2.13
Be aware of fiber guide protruding downward until
splice is acutated
Caution: Do NOT PUSH UP fiber guide or connector may
pop out from cable holder
2.16
Check for marking on buffer at the end of buffer clamp.
If marking is not at this position, pull out the sliding
head and check for fiber length again per Section 2.10.
And insert fiber again per Section 2.15