background image

Fitting Instructions

Before assigning any respirator to be worn in a contaminated 
area, we recommend that a qualitative or quantitative fit check 
be performed before entering the workplace.

Fitting instructions must be followed each time the respirator is worn.

Place the respirator over the mouth and nose, then pull the 

1. 

harness over the crown of the head.
Take the bottom straps in both hands, place them at the back 

2. 

of the neck and hook them together.
Tighten the top straps first by pulling on ends to achieve a 

3. 

comfortable and secure fit.
Tighten bottom straps using either front or rear adjustments. 

4. 

(Strap tension may be decreased by pushing out on back side 
of buckles).

Fit Check 

Perform a positive and/or negative pressure fit check each time 
the respirator is donned.

Positive pressure Face Fit check (all Filters except 3M™ 
6035, 6038 / 2000 Series Filters).

Place the palm of the hand over the exhalation valve cover 

1. 

and exhale gently.
If the respirator bulges slightly and no air leakage between 

2. 

the face and the respirator is detected, a proper fit has been 
achieved.
If air leakage is detected, reposition the respirator on the 

3. 

face and/or readjust the tension of the strap to eliminate the 
leakage.
Repeat the above face fit check.

4. 

If you cannot achieve a proper fit, do not enter the 

5. 

contaminated area. See your supervisor.

Negative pressure face fit check (3M™ 6035, 6038 / 2000 
Series Filters)

Push the filter cover down (6035, 6038) or press your thumbs 

1. 

into the central indentation of the filters (2000 series), inhale 
gently and hold your breath for five or ten seconds.
If the respirator collapses slightly, a proper fit has been 

2. 

achieved.
If air leakage is detected, reposition the respirator on the 

3. 

face and/or readjust the tension of the straps to eliminate the 
leakage.
Repeat the above face fit check.

4. 

If you cannot achieve a proper fit, do not enter the 

5. 

contaminated area. See your supervisor.

Materials

PART

MATERIAL

Face Mask

Thermoplastic Elastomer

Head Harness

Polyethylene

Head Strap

Polyester / cotton / Polyisoprene

Inhalation Valve

Polyisoprene

Exhalation Valve

Silicone Rubber

Gasket

Silicone Rubber

6000 Filter Body

Polystryrene

6000 Filter Element

Activated / Treated Carbon

5000 / 2000 Series Filter material

Polypropylene

Please recycle. 

© 3M 2010. All rights reserved.

3M a/s 

Sikkerhedsprodukter

Fabriksparken 15

DK-2600 Glostrup

Telefon: 43 48 01 00

Fax: 43 96 85 96

E-mail: [email protected]

www.3Msikkerhed.dk

Important Notice 

3M does not accept liability of any kind, be it direct or consequential (including, but not limited to, loss of profits, business and/or goodwill) 
arising from reliance upon any information herein provided by 3M. The user is responsible for determining the suitability of the products 
for their intended use. Nothing in this statement will be deemed to exclude or restrict 3M’s liability for death or personal injury arising from 
its negligence.

Spare parts

PART

MATERIAL

6895

Inhalation Gasket

501

Retainer for 5000 Series Filters

603

Particulate Filter Platform

105

Face Seal Cleaner

S-200

Supplied Air Regulator

106

Half Mask Carry Case

  Respiratory Protection is only effective if it is correctly 
selected, fitted and worn throughout the time when the 
wearer is exposed to respiratory contaminants.

3M offers advice on the selection of products, and training in the 
correct fitting and usage.

For more information on 3M products and services please 
call the 3M Health & Safety Helpline.

DS6

5/

000

12

5-

1