6
Inspection:
1. Make sure unit is straight and operates smoothly.
2. Make sure the label is affixed to unit.
3.
Make sure trigger stop is not bent or damaged.
4.
Make sure cables are not kinked, frayed or damaged.
5.
Make sure metal components are not damaged.
6.
Make sure metal spoons and conical end fitting operate smoothly
and no metal burrs have occurred.
7.
When reusing a previously drilled hole, always inspect the
hole carefully.
Storage and Cleaning:
1.
Blow off unit after each use with compressed air.
2.
Store in clean dry environment.
3.
Store in secure locked area.
4.
Store and put away at the end of each day’s work.
5.
Do not pile any objects on top of unit during storage.
6.
Keep unit free of grease, oils and dirt.
7.
Avoid lending your unit to other workers.
Disposal:
1. Dispose of unit after any fall has occurred.
2. Dispose of unit if cable becomes kinked or bent.
3. Dispose of unit if trigger stop is bent or damaged.
4. Dispose of unit if trigger action is rough or sticky.
5.
Dispose of unit if return wire becomes bent or frayed.
6.
Proper disposal requires the unit’s spoons be cut off the
When installing the SafeClaw, place your thumb inside the anchor loop
and your first two fingers around the trigger. Retract the trigger until
the spring bottoms out. With your other hand, pinch the two spoons
between your thumb and index finger. Hold the trigger fully retracted
while inserting the unit into bottom of the hole.
Company Logo
Hole Diameter/Size
Manufactured Date
Batch Number
Model Number
ANSI Z359.1 Mark
Warning Instructions
Compliance:
ANSI Z359.1-07 5,000 lbs.
OSHA
1910.66 & 1926.502
Model # 4075 / Batch 000
Manufactured 00/00/00
US Patent 6,729,821
US Patent 7,011,281
US Patent 7,357,363
3/4”
Warning:
All persons using this
equipment must read,
understand and follow all
instructions. Failure to do
so may result in serious
injury or death.
WARNING DO NOT use in
wet or uncured concrete.
Use in normal weight
concrete with a compression
strength at least 3,000 PSI
(20.7 MPa) Use for Fall
Protection Only
Patent Markings
Main Cable
7x19 Aircraft Cable
End Termination
304 Stainless Steel
Spoons
304 Stainless Steel
Bushing Guide 304 Stainless Steel
Stop sleeve
304 Stainless Steel
Trigger
6061 T-6 Aluminum
Spring
Zinc Coated Spring Steel
Swage
Zinc Coated Copper
Return Wire
1x19 Aircraft Cable
Plastics Polyurethane
If a SafeClaw becomes stuck, insert a punch, screwdriver
or pointed object into the hole until the tip rests on the
striker plate Give a LIGHT, blunt tap with a hammer or
suitable object. The Striker Plate will be easily visible at
the edge of the hole.
SafeClaw Anchor inserted
into a 3” hole
The metal Stop Sleeve
must be inserted half
way into the hole.
1-800-560-1094
SafeClaw
Reference #
70071532330