![3M 2529-AS Instructions Manual Download Page 9](http://html1.mh-extra.com/html/3m/2529-as/2529-as_instructions-manual_442832009.webp)
9
5.0 Fiber Repositioning for
3M
™
Fibrlok
™
II Angle Fiber
Splice 2529-AS
5.1
If high loss is observed after a splice has been
actuated, it is possible that the fiber ends are
separated. In this case, lift the splice cap and
reposition fiber ends, as instructed below.
Note: If the splice has been in service, place the splice
back into the tool. Insert the fiber holders into the
tool and push them towards the splice. Recreate
fiber bows on both sides of the splice and close
the fiber clamps to maintain the angled cleaved
fiber keying.
Note: Do not completely remove fiber from Fibrlok
splices.
5.2
Place the two fiber holders into Fibrlok assembly tool
base and open the guide funnel, middle covers and
the back clamp on the fiber holder.
5.3
Insert Fibrlok into the tool and lay the fibers in
the appropriate channels so there is no twist in the
fibers. Ensure the fiber holders are fully inserted into
the tool.
5.4
Lightly close the fiber clamp on the holder so the
fiber can move under the clamp.
5.5
Create a fiber bow and then fully clamp the fiber.
Repeat with the second fiber. Ensure second bow is
the same size as first bow.
5.6
While the splice is in the splice holding cradle, insert
the short prongs of the 3M
™
Fibrlok
™
II Splice cap
lifter into the two holes on the side of the splice.
The cap lifter will be at an angle to the splice. The
long prongs will be resting against the top of the
splice cap.
5.7
Slide the bottom of the cap lifter inward until it is in
a vertical position, lifting the splice slightly out of the
cradle.