27
How to Connect
Pegasus™ NX?
Wiring Instructions
Warning:
Wiring should be done by the trained 3i-Corporation authorized service personnel only.
Never install the device during lightning or storm.
Always use genuine 3i-Corporation approved accessories with the device.
Turn OFF power supply during wiring.
Wiring Example
Pegasus™ NX is built in four terminals:
R1
,
T1
,
RING
and
TIP
for alarm panel connections. These are fully compatible
with any alarm panel that follows Contact ID Protocol.
Telephone Line
and
Handset
terminals that can be used to connect wires from telephone exchange and telephone
handset respectively. Use the RJ31X or RJ38X phone jack for connection.
The
programmable SPDT relay output
can be used for various crucial operations. For example, switching a high
current powered bell or siren.
Three programmable open collector outupts
can be used to activate a buzzer or strobe light, open or close doors etc.
When any of the three on board programmable open collector outputs is activated, Pegasus™ NX triggers any device
connected to it.
10
Summary of Contents for Pegasus NX
Page 32: ...28 ...
Page 36: ...32 ...
Page 37: ...33 Single Mode Normally Close N C Contacts without End of Line EOL Resistor ...
Page 38: ...34 Single Mode Normally Close N C Contacts with End of Line EOL Resistor ...
Page 39: ...35 Single Mode Normally Open N O Contacts with End of Line EOL Resistor ...
Page 42: ...38 Double Mode Normally Close N C Contacts without End of Line EOL Resistor ...