THERMOSALD ISC – MANUAL QUICK START
Rev. 2010 / 03
Manual cod.: 3ES080x_V5.1_QS_EN Page Nr. 15 Tot. Nr . 20
Includes all previous models
4.8 - THEORETICAL CALCULATIONS AND DIAGNOSTIC PROCEDURES WITH THE AID OF THE DATA
INPUT PANEL
1)
Access the DIAGNOSTIC – THEORETICAL CALCULATION submenu.
2)
Enter the data that concern the shape of the strip: length, width, cross-section, number of strips in series, number of
strips in parallel.
3)
Enter the data and quit.
DIAGNOSTIC
1)
Select the DIAGNOSTIC – ANALISYS submenu.
2)
Scroll the diagnostic video-pages by using the ARROW UP – DOWN buttons. These pages contain the electrical
specifications that concern the sealing strip: maximum effective currents, resistance, full-wave effective currents,
full-wave effective power.
3)
Each video page indicates 3 values that relate to the same variable under different conditions i.e.: THEORETICAL
VALUES, CALIBRATION SETTINGS, REAL TIME VALUE, in particular:
PAGE
1:
IMAX=
I0=
I=
Where IMAX stands for the maximum pulsed effective currents of the temperature controller, I0 represents the full-
wave effective current for calibration and I is the actual full-wave effective current
PAGE 2:
R THEORETICAL =
R0=
R=
Where R THEORETICAL stands for the theoretical resistance of the temperature controller, R0 is the calibration
resistance and R represents the actual resistance.
PAGE 3:
I THEORETICAL =
I0=
I=
PAGE 4:
V THEORETICAL =
V0=
V=
PAGE 5:
P THEORETICAL =
P0=
P=
4) Particularlty useful information on the system conditions can be obtained
by comparing the three variables so that any malfunctioning and diagnostic
problems can be dealt with remotely.