16
Calibration of the platform
From the main menu, select
Calibration
. The print head will travel to the front of the chamber and heat up to
235
o
C. Clean the nozzle with tweezers and choose
Next step
.
The print head will move to the first calibration point, located above nut nr 1. By turning the nut will cause the
printer’s backlight to change color from white to green.
NOTICE!
A green light does not always mean that the printing platform is properly calibrated. If the head moves
to the calibration point and printer light turns green, turn the nut to the right until the light turns white. Then
turn the nut to the left.
A change in the back light from white to green indicates the appropriate level.
Choose
Next step
. The head will travel to the next position.
Repeat the procedure from steps 2 and 3 for the remaining calibration points.
After calibrating the head in the last position, choose
Exit
. The head will travel to the default position. Following
this procedure, the table is correctly calibrated.
1.
2.
3.
4.
5.
6.
17