74
3D SYSTEMS, INC
.
PN:80-D48 REV A
Exhaust filter replacing
Part required :
•
Filter element : 80-1833
Caution : Personal Protective Equipment (PPE) must be used to protect the user against health or
safety risks during working tasks . Wear disposable rubber gloves, anti-static coverall, anti-static safety
shoes and safety glass . Wear disposable dust mask rated FFP3 or N99 level protection at minimum ; we
recommand the use of powered air purifying respirator .
Procedure:
1 . Make sure the gas and purge are not activated .
2 . Open the door located below the front doors of the machine (1), and the left side door (2) .
3 . Close the input valve (3) .
4 .
Remove the filter guard (4).
5 .
Remove the filter element. Dispose it in accordance with all local/regional/national/, state and federal regulations.
WARNING : FLAMMABLE POWDERS .
PLACE THE USED FILTER ELEMENT IN A CLOSED METALLIC CONTAINER IN A ROOM WITH FIRE DETECTION .
6 .
Clean the filter guard with the use of damp cotton cloth, and install the new filter element.
7 .
Replace the filter guard, and open the input valve.
8 . Close the left side door and the door located below the front doors of the machine .
4
Filter guard
3
Input valve
2
1