4.3  Lighting modes (available only at SCALEREO-Desk) 

There are 7 different modes for the LED light system: 

 

 

OFF 

All 

Central 

 

Ring Left 

Right Middle 

Ring Right 

Ring All   

 

4.4  Headtracking modes 

4.4.1 Freeze  

 

Press “

Freeze

” to instantly pause the headtracking system. The user´s current position 

is “freezed” and the user is no more tracked, thus he needs to re-position himself in this 
position to get correct 3D. 

o

 

This mode is useful to temporally use the system with multiple users simultaneously, e.g. to explain something   

  

 

Press “

Freeze

” again to run the headtracking system in its last used mode 

4.4.2 Headtracking working modes  

 

Press “

Mode

” to toggle between the 2 pre-activated headtracking modes:  

o

  FINE  

–   Continuous, immediate tracking of the viewing position 

  The image is tracked to the user's current position even if the user's 

position changes only very slightly. 

  When this mode is activated, "User Tracking FINE" appears briefly on 

the screen. 

o

  OFF 

–   No active tracking of the 3D viewing position  

  The  user  must  be  positioned  optimally  in  the  viewing  zone  located 

centrally in front of the display. 

 

Permanent overlay of “User Tracking OFF”. 

 

If required, the following two additional headtracking modes can optionally be enabled in 
the settings menu (refer to the user manual for detailed information):  

o

  COARSE 

–   “Rough” tracking of the viewing position with low hysteresis 

 

o

  2D FORCED 

–   Forced 2D visualization   

When the headtracking system is 

“OFF” or in “freeze mode”,  

the display works in untracked 

“BlackMatrix” mode, which means that  

certain black areas are projected into the edge-areas of the viewing zone. 

 

This simplifies the correct positioning within the viewing zones, even for more than one user.

 

Summary of Contents for SCALEREO

Page 1: ...h integrated microscope optics stereo camera unit and flexible lighting system SCALEREO AddOn 3D video extension kit including a 3D camera add on module image 3b to upgrade existing optical microscopes e g Leica M Series Olympus Zeiss to become a digital 3D video microscope system 1 Start Up 1 1 System components 1 3D Display 2 Signal Processing Unit SPU 3a Desk Microscope Unit 3b AddOn Module 4 S...

Page 2: ...ble USB to the SPU Connect the power cable to the SPU 1 3 Start the system Switch on the main switch Briefly press the power button front side of SPU to start the system Wait until the system has completely booted and 3D visualization is provided To deinstall the system follow the steps above but in reverse order 2 Usage Requirements It is absolutely essential to observe these 3 basic requirements...

Page 3: ... press 0 5s on button F to set the focus plane upwards Long press 0 5s on button F to set the focus plane downwards 4 2 Photo video documentation 4 2 1 freeze image Press Freeze Image to temporarily freeze the current image on the screen PAUSE Press Freeze Image again to go back to LIVE image visualization 4 2 2 record photo video Short press 0 5s Photo Video to save the current image as a screens...

Page 4: ...e tracking of the viewing position The image is tracked to the user s current position even if the user s position changes only very slightly When this mode is activated User Tracking FINE appears briefly on the screen o OFF No active tracking of the 3D viewing position The user must be positioned optimally in the viewing zone located centrally in front of the display Permanent overlay of User Tra...

Reviews: