Resetting the Unit to Factory Defaults
29
Using the Reset to Default Icon
To reset the wireless bridge unit configuration settings to their factory default values,
follow these steps:
1
From the Wireless Bridge Configuration screen (see “Selecting a Bridge to Configure”
on page 15), select the
Tools
tab.
2
Double-click the
Reset To Default
icon.
The Reset To Default screen appears, asking you to verify that you want to restart the
bridge unit.
3
Click
Yes
to restart the unit.
Resetting by Using the Configuration Button
You can also reset the 3Com Wireless Building-to-Building Bridge to factory default
settings without using the Bridge Manager:
1
Disconnect power to the bridge.
2
Insert one end of an extended paper clip into the small hole labeled
Config.
(located
near the serial port on the bridge back panel) to press the configuration button.
3
While keeping the configuration button pressed, reconnect power to the bridge.
Press the configuration button for at least five seconds after power is applied. The
bridge will be reset to factory defaults once the lights start to blink.