background image

 

Technical Information

 

Trouble Shooting

 

If you have a problem, the paragraphs below offer some 

 

guidance for solving it. Check the status of the LEDs on 

 

the front panel of the chassis, as described adjacent to 

 

this paragraph and in the SuperStack II Advanced RPS 

 

User Guide, part number DUA1607-0AAA0X. 

 

Should you be unable to rectify the problem, consult your 

 

supplier with the following information:

 

product number and power module serial number

 

a brief description of the fault

 

Mechanical

 

Weight

 

550 g (1.21 lb)

 

Size

 

272  x  87 mm (10.7 x 3.4 in)

 

Electrical - Maximum Current Available

 

3C16072

 

3C16073

 

+12.6 volts 

 

2.5 amperes

 

2.5 amperes

 

- 12 volts

 

1 ampere

 

1 ampere

 

+5 volts

 

8.5 amperes

 

15 amperes

 

Power Consumption

 

60W Power Supply Module

 

Typical Input Power

 

:

 

 100 watts

 

Total output power must not exceed 60 watts.

 

100W Power Supply Module

 

Typical Input Power

 

 

167 watts

 

Total output power must not exceed 100 watts.

 

Observed 

 

Symptoms

 

Possible Fault

 

Mains present, 

 

No Input LED ON

 

1/

 

Ensure AC Cable is correctly 

 

connected.

 

2/

 

Internal AC fault.

 

Power Module 

 

present,

 

No Output LED ON

 

1/

 

DC Cable not connected.

 

2/

 

SuperStack II unit not 

 

connected.

 

3/

 

SuperStack II unit does not 

 

require RPS power.

 

4/

 

SNMP management has 

 

disabled the Power Module.

 

Power Module 

 

present,

 

Yellow LED ON

 

1/

 

Power Module connected to 

 

SuperStack II unit whose DC 

 

requirement exceeds the 

 

available DC output power.

 

2/

 

Power Module’s outputs are 

 

out of specification.

 

3/

 

Power Module has failed.

 

LEDs

 

Power Module Requirements

 

The tables below detail the Power Modules needed to 

 

provide sufficient power to the different SuperStack II 

 

units. Products marked * have the auto-enable feature 

 

(

 

see

 

 

 

SuperStack II Advanced RPS User Guide, 

 

part number DUA1607-0AAA0X

 

).

 

The details are, we believe, correct at the time of printing 

 

this manual, but may change. If you are in doubt, consult 

 

the product user guide or your supplier for the latest 

 

information.

 

 

 

LED

 

Function

 

State

 

Indication

 

Input  

 

OK -

 

Green

 

Denotes 

 

presence 

 

of AC 

 

power.

 

ON

 

AC is connected to 

 

relevant input and is OK.

 

OFF

 

AC is not connected to 

 

relevant input or there is 

 

an AC fault. 

 

Output

 

OK -

 

Green

 

Power 

 

Module is 

 

operating.

 

ON

 

Power Module is 

 

supplying power to a 

 

SuperStack II unit.

 

OFF

 

Power Module is not 

 

present or Power Module 

 

is not required to deliver 

 

power or Power Module is 

 

disabled by management.

 

Output

 

Fault -

 

Yellow

 

Power 

 

Module 

 

fault.

 

ON

 

Power Module is required 

 

to deliver power but 

 

cannot.

 

OFF

 

Power Module should be 

 

OK.

 

Over-

 

temp -

 

Yellow

 

Temper-

 

ature in 

 

Advanced 

 

RPS and 

 

fan state.

 

ON

 

Temperature is too high 

 

or fan has failed.

 

OFF

 

Temperature is OK.

 

Fan OK.

 

SuperStack II Products  requiring a 60 Watt 

 

Power Module (numerical order)

 

3C215A

 

Hub 100 Management Unit

 

3C250-T4

 

Hub 100 T4 (also with 3C252 or 3C262 

 

Module fitted)

 

3C250A-TX/I

 

Hub 100 TX (also with 3C252 or 3C262 

 

Module fitted) 

 

*3C7204A

 

AccessBuilder 2204

 

*3C7208A

 

AccessBuilder 2208

 

3C8200C

 

NetBuilder 200

 

3C8201C

 

NetBuilder 201

 

3C8221C

 

NetBuilder 221

 

3C8222C

 

NetBuilder 222

 

3C8223C

 

NetBuilder 223

 

3C8224C

 

NetBuilder 224

 

3C8227C

 

NetBuilder 227

 

3C8228C

 

NetBuilder 228

 

3C8252A

 

LinkConverter II 252

 

3C8254A

 

LinkConverter II 254

 

3C8323C

 

NetBuilder 323

 

3C8327C

 

NetBuilder 327

 

3C8352A

 

LinkConverter II 352

 

3C8354A

 

LinkConverter II 354

 

3C8421C

 

NetBuilder 421

 

3C8422C

 

NetBuilder 422

 

3C8423C

 

NetBuilder 423

 

3C8424C

 

NetBuilder 424

 

3C8427C

 

NetBuilder 427

 

3C8523C

 

NetBuilder 523

 

3C8527C

 

NetBuilder 527

 

*3C16405

 

PS Hub 40 12-port (also with a valid 

 

combination of 3C1206X Transceiver 

 

Modules or 3C16060 Bridge 

 

MicroModules fitted)

 

*3C16406

 

PS Hub 40 24-port (also with a valid 

 

combination of 3C1206X Transceiver 

 

Modules or 3C16060 Bridge 

 

MicroModules fitted)

 

3C16665A

 

Hub 10 Fiber (also with 3C16630A or 

 

3C16632 Management Module and 

 

3C1206X Transceiver Module fitted)

 

3C16670A

 

Hub 10 12-port (also with 3C16630A or 

 

3C16632 Management Module and 

 

3C1206X Transceiver Module fitted)

 

3C16671A

 

Hub 10 24-port (also with 3C16630A or 

 

3C16632 Management Module and 

 

3C1206X Transceiver Module fitted)

 

3C16672A

 

Hub 10 Telco (also with 3C16630A or 

 

3C16632 Management Module and 

 

3C1206X Transceiver Module fitted)

 

3C16900A

 

Switch 1000 24-port (also with 3C1206x 

 

or 3C16920/2 modules fitted)

 

3C16901A

 

Switch 1000 12-port (also with 3C1206x 

 

or 3C16920/2 modules fitted)

 

*3C16902

 

Desk Top Switch (also with 3C1206x or 

 

3C16920/2 modules fitted)

 

3C16940A

 

Switch 3000 FX (also with 3C1206x or 

 

3C16920/2 modules fitted)

 

3C16941A

 

Switch 3000 TX (also with 3C16920/2 

 

modules fitted)

 

3C32700A

 

Switch 2700 OC-3 Multimode ATM

 

3C32710A

 

Switch 2700 DS-3 ATM

 

3C32711A

 

Switch 2700 OC-3 Singlemode ATM

 

3C510510B

 

Hub TR 12-port (also with mixes of 

 

3C51050X RI/RO Modules and 3C510502 

 

or 3C510505 RMON Modules fitted)

 

3C510511B

 

Hub TR 24-port  (also with mixes of 

 

3C51050X RI/RO Modules and 3C510502 

 

or 3C510505 RMON Modules fitted)

 

3C510600

 

Switch 2000

 

3C94103R-

 

CSIX

 

Open Partner Boundary Router 1

 

3C94103R-

 

CSD

 

Open Partner Boundary Router 2

 

3C94103R-

 

CSDI

 

Open Partner Boundary Router 3

 

3C94103R-

 

CSE

 

Open Partner Boundary Router 4

 

3C94117C-

 

XS

 

Open Partner Comms Server 16-port

 

3C94133C-

 

XS

 

Open Partner Comms Server 32-port

 

3C94101M-

 

SDEK

 

Open Partner Single Slot SS II Access

 

3C220000A

 

Switch 2200 without modules

 

Superstack II Products requiring a 100 Watt 

 

Power Module (numerical order)

 

3C16900A

 

Switch 1000 24-port fitted with 3C16930 

 

module

 

3C16901A

 

Switch 1000 12-port fitted with 3C16930 

 

module 

 

*3C16902

 

Desk Top Switch  fitted with 3C16930 

 

module

 

3C16940A

 

Switch 3000 FX  fitted with 3C16930 

 

module

 

3C16941A

 

Switch 3000 TX  fitted with 3C16930 

 

module

 

*3C16942

 

Switch 3000 TX 12-port (also with 

 

3C16920/2 or 3C16930 modules fitted)

 

3C220000A

 

Switch 2200 with modules

 

SuperStack II Products  NOT supported by the 

 

Advanced RPS

 

3C81600

 

Enterprise Manager (including various 

 

RMON Probes)

 

3C8930A

 

DC Voltage Converter 3-port

 

3C8960A

 

DC Voltage Converter 6-port

 

3C16010/1/2

 

UPS

 

3C565047A

 

RPS

Reviews: