The numbers in this diagram refer to numbered sections in the 
text.

Front Panel

1

24 RJ-45 10/100 Ports and 1 RJ-45 1000 Port

WARNING:

 RJ-45 ports.

 These are shielded RJ-45 data 

sockets. They cannot be used as telephone sockets. Only 
connect RJ-45 data connectors to these sockets. Either 
shielded or unshielded data cables with shielded or 
unshielded jacks can be connected to these data sockets.

AVERTISSEMENT: Les ports RJ-45.

 Il s’agit de prises 

femelles blindées de données RJ-45. Vous ne pouvez pas 
les utiliser comme prise de téléphone. Branchez unique-
ment des connecteurs de données RJ-45 sur ces prises 
femelles. Les câbles de données blindés ou non blindés, 
avec les jacks blindés ou non blindés, l’un ou l’autre, peu-
vent être branchés à ces prises de courant de données.

WARNUNG: RJ-45-Anschlüsse. 

Dies sind abgeschirmte 

RJ-45-Datenbuchsen. Sie können nicht als Telefon- 
anschlußbuchsen verwendet werden. An diesen Buchsen 
dürfen nur RJ-45-Datenstecker angeschlossen werden. 
Diese Datenstecker können entweder mit abgeschirmten 
oder unabgeschirmten Datenkabeln mit abgeschirmten 
oder unabgeschirmten Klinkensteckern verbunden wer-
den.

10BASE-T/100BASE-TX Ports

The Baseline 10/100 Switch 24 Port 10BASE-T/100BASE-TX plus 
1-Port 1000BASE-T has 24 10/100Mbps auto-negotiating ports.

Ports 1–23 are MDIX ports. Each can be connected to a device 
with an MDI port (such as a workstation) using a normal ‘straight 
through’ TP (twisted pair) cable. Alternatively, you can connect to 
a device with MDIX ports using ‘cross-over’ TP cable.

Port 24 is ‘switch selectable’ MDI/MDIX using the MDI switch, as 
described in 

2

. Using this port, you can connect to any other 

device without the need for ‘cross-over’ cable.

Ports 1 to 24 are auto-negotiating: their speed and duplex mode 
(half duplex or full duplex) are automatically determined by the 
capabilities of the connected device. Each port can be connected 
to either a 10BASE-T or a 100BASE-TX device.

CAUTION: 

The Baseline 10/100 Switch supports full 

duplex auto-negotiation. If the connected device does not 
support auto-negotiation, the Switch will operate in half 
duplex mode (even if the device is operating in full duplex 
mode). In such a configuration, you may notice some 
degradation of network performance. 3Com recommends 
that you use devices that are capable of auto-negotiation 
(and that you ensure that auto-negotiation is enabled, if 
it is a configurable option).

1000BASE-T Port

Port 25 is a 1000BASE-T port capable of auto-negotiation with 
the connected port to operate at 1000BASE-T full duplex. It 
auto-senses an MDI/MDIX connection and can be used to connect 

to either another 1000BASE-T switch port or to a 1000BASE-T 
server or workstation without additional configuration.

Connecting to a Network Device

To connect a device to the Baseline 10/100 Switch 24 Port 
10BASE-T/100BASE-TX plus 1-Port 1000BASE-T, use Category 5 
unshielded or shielded (screened) 100 Ohm TP cable (or 
Category 3 cable for a 10Mbps connection). The maximum length 
of cable for each connection is 100m (328ft). Connect one end of 
the cable to an RJ-45 port on the Baseline 10/100 Switch, and 
the other end to the appropriate RJ-45 port on the connecting 
device.

Connecting to another Switch or Hub

If you connect two Baseline 10/100 Switch 24 Port 
10BASE-T/100BASE-TX plus 1-Port 1000BASE-T units 
together, 3Com recommends that you use the 
1000BASE-T ports on both units for the link. You must 
use Category 5 cable when connecting the units.

1000BASE-T connection:

 To connect a Baseline 10/100 Switch 

24 Port 10BASE-T/100BASE-TX plus 1-Port 1000BASE-T to 
another Switch using the 1000BASE-T port, use a normal ‘straight 
through’ cable and connect each end to the 1000BASE-T port on 
each unit.

100BASE-TX connection:

 To connect the Baseline 10/100 Switch 

24 Port 10BASE-T/100BASE-TX plus 1-Port 1000BASE-T to a 
SuperStack 3 hub using a normal ‘straight through’ cable, 
connect any port on the Baseline 10/100 Switch 24 Port 
10BASE-T/100BASE-TX plus 1-Port 1000BASE-T to the MDI/MDIX 
port on the hub, as shown below. Ensure that the MDI switch on 
the hub is in (MDI).

An alternative method of connecting the Baseline 10/100 Switch 
to a hub using a normal ‘straight through’ cable is to connect any 
MDIX port on the hub to the MDI/MDIX port on the Baseline 
10/100 Switch, ensuring that its MDI Switch is set to in (MDI). 
You can use ‘cross-over’ TP cable to connect any MDIX port on 
the Baseline 10/100 Switch to any MDIX port on a hub.

H

OW

 

TO

 U

SE

 

THE

 B

ASELINE

 10/100 S

WITCH

 24-P

ORT

!

2

Summary of Contents for SuperStack 3 3C16467

Page 1: ...1000BASE T port is a fixed speed port that operates in full duplex mode The Baseline 10 100 Switch is suited for office use where it can be free standing or rack mounted in a wiring closet or equipment room The Baseline 10 100 Switch comes with One power cord Four self adhesive rubber pads One mounting kit The Switch can be powered either from the AC mains supply or through an optional 3Com SuperS...

Page 2: ... in full duplex mode In such a configuration you may notice some degradation of network performance 3Com recommends that you use devices that are capable of auto negotiation and that you ensure that auto negotiation is enabled if it is a configurable option 1000BASE T Port Port 25 is a 1000BASE T port capable of auto negotiation with the connected port to operate at 1000BASE T full duplex It auto ...

Page 3: ...e side of the case is not restricted 3Com recommend that you provide a minimum of 25mm 1in clearance The air is as free from dust as possible Temperature operating limits are not likely to be exceeded It is recommended that the unit is installed in a clean air condi tioned environment It is always good practice to wear an anti static wrist strap when installing network equipment connected to a gro...

Page 4: ...ady fitted 1 Place the unit the right way up on a hard flat surface with the front facing towards you 2 Locate a mounting bracket over the mounting holes on one side of the unit 3 Insert the two screws supplied in the mounting kit and fully tighten with a suitable screwdriver 4 Repeat the two previous steps for the other side of the unit 5 Insert the unit into the 19 inch rack and secure with suit...

Page 5: ...ondaire de connexion portant l appellation Neutre et avec raccordement direct à la terre masse Cordon électrique Il doit être agréé dans le pays d utilisation Bitte unbedingt vor dem Einbauen des Baseline 10 100 Switch 24 Port 10BASE T 100BASE TX plus 1 Port 1000BASE T Einheit die folgenden Sicherheitsanweisungen durchlesen WARNUNG Die Installation und der Ausbau des Geräts darf nur durch Fachpers...

Page 6: ...d expense provide a software update which would effect the proper performance of such product repair such product deliver to Customer an equivalent product to replace such product or if none of the foregoing is feasible refund to Customer the purchase price paid for such product Any software update or replaced or repaired product will carry a Year 2000 Warranty for ninety 90 days after purchase OB...

Page 7: ...nd by the laws of the United States excluding their conflicts of laws principles The United Nations Convention on Contracts for the International Sale of Goods is hereby excluded in its entirety from application to this Limited Warranty 3Com Corporation 5400 Bayfront Plaza P O Box 58145 Santa Clara CA 95052 8145 408 326 5000 August 2000 3Com reserves the right to modify or cancel this offering at ...

Page 8: ...s of the United States If there is any software on removable media described in this documentation it is furnished under a license agreement included with the product as a separate document in the hard copy documentation or on the removable media in a directory file named LICENSE TXT If you are unable to locate a copy please contact 3Com and a copy will be provided to you Unless otherwise indicate...

Reviews: