Numbered elements in this diagram refer to numbered sections in the
text. These numbers, in bold, are used as references.

Front Panel

1

12 or 24 RJ45 10Base-T Ports

WARNING:

RJ-45 Ports. These are shielded RJ-45 data sockets.

They cannot be used as standard traditional telephone sockets,
or to connect the unit to a traditional PBX or public telephone
network. Only connect RJ-45 data connectors, network tele-
phony systems, or network telephones to these sockets.
Either shielded or unshielded data cables with shielded or
unshielded jacks can be connected to these data sockets.

AVERTISSEMENT:

Points d’accès RJ-45. Ceux-ci sont protégés

par des prises de données. Ils ne peuvent pas être utilisés comme
prises de téléphone conventionnelles standard, ni pour la con-
nection de l’unité à un réseau téléphonique central privé ou pub-
lic. Raccorder seulement connecteurs de données RJ-45,
systèmes de réseaux de téléphonie ou téléphones de réseaux à
ces prises.
Il est possible de raccorder des câbles protégés ou non protégés
avec des jacks protégés ou non protégés à ces prises de don-
nées.

WARNHINWEIS:

RJ-45-Porte. Diese Porte sind geschützte Dat-

ensteckdosen. Sie dürfen weder wie normale traditionelle Tele-
fonsteckdosen noch für die Verbindung der Einheit mit einem
traditionellem privatem oder öffentlichem Telefonnetzwerk
gebraucht werden. Nur RJ-45-Datenanscluße, Telefonnetzsysteme
or Netztelefone an diese Steckdosen anschließen.
Entweder geschützte oder ungeschützte Buchsen dürfen an diese
Datensteckdosen angeschlossen werden.

Either shielded or unshielded data cables with shielded or unshielded jacks
can be connected to these data sockets.

2

MDI Switch

Ports 1 to 11 (12-port hub) and 1 to 23 (24-port hub) are fixed as MDIX
ports so that they can be connected directly to DTE (workstations or other
equipment) which have MDI ports using normal ‘straight through’ TP
cables.

Port 12 (12-port hub) and 24 (24-port hub) are switch selectable using the
MDI Switch. The ports can be MDIX ports (to connect directly to DTE like
the other ports), or MDI ports (to connect to other repeaters using a
normal ‘straight through’ TP cable).

To connect two Baseline Hubs, connect port 12 or 24 on unit 1 to any
port on unit 2. Ensure that the MDI switch on unit 1 is IN (MDI) and that
if port 12 or 24 is used on unit 2, the MDI switch is OUT (MDIX).

3

TP Status LEDs

The TP Status LEDs show the partition state of a port and whether or not
the Link Pulse signal is present on the segment connected to a port:

If these checks do not identify the cause of a problem, it may be that the
Baseline Hub or the device connected to the port is faulty. Contact your
supplier for further advice.

H

OW TO

U

SE THE

B

ASELINE

H

UB

1x

13x

7x

19x

6x

18x

12x

24

3C16641A SuperStack 3

®

MDIX

MDI

Baseline Hub

1

5

9

2

6

10

3

7

11

4

8

12 TCVR

Collision Power

Traffic

13

17

21

14

18

22

15

19

23

16

20

24

link OK

partition

no link

green =

flashing green =

off =

2

4

7

5 6

1

8

9

10

11

Status

3

Out

In this position you can connect port 12 or 24 to a
workstation or any other DTE using a normal ‘straight
through’ TP cable.

In

In this position you can connect port 12 or 24 to any
MDIX port on another 10BASE-T repeater using a normal
‘straight through’ TP cable.

MDIX

MDI

Green

The Link Pulse signal is being received and the segment attached
to the port is functional.

Flashing
green

The port is partitioned from the network.

Check the connections and the cable for any breaks in the

segment.

Make sure the transceiver attached to the DTE is correctly

connected and powered up.

Check for illegal 802.3 configurations, in particular, loops.

If the cause of the partition is found and corrected, the segment is
reconnected automatically, after the first valid packet is
transmitted to, or received from the segment.

Off

The Link Pulse signal is not being received.

Check that the attached DTE is switched on.

Check that the attached transceiver is not faulty.

If it is port 12 or 24 or an inter-repeater link, check the setting

of the MDI switch.

Carry out the checks recommended for when a Status LED is

flashing green.

Check for no more than 4 repeater stacks in series, and that

cable lengths do not exceed the maximum specified in the
standard for that medium.

Set switch to

MDI (in)

Switch set to MDIX (out)

if port 24 used

Unit 2

Unit 1

2

Summary of Contents for SuperStack 3 3C16440A

Page 1: ...s a single IEEE 802 3 Ethernet repeater hub there can be a maximum of four Baseline Hubs between any two pieces of Data Terminal Equipment DTE workstations or other equipment on the same network The B...

Page 2: ...DI ports to connect to other repeaters using a normal straight through TP cable To connect two Baseline Hubs connect port 12 or 24 on unit 1 to any port on unit 2 Ensure that the MDI switch on unit 1...

Page 3: ...lat surface or stacked with another SuperStack 3 product of the same dimensions Use the two reduced height pads and two of the standard height pads if the unit is to be stacked on a SuperStack 3 unit...

Page 4: ...masse Cordon lectrique Il doit tre agr dans le pays d utilisation Bitte unbedingt vor dem Einbauen des Baseline Hub Einheit die fol genden Sicherheitsanweisungen durchlesen WARNUNG Die Installation u...

Page 5: ...re returning the unit product number and serial number printed on a label on the back of the unit a brief description of the fault When returning any equipment to your supplier ensure that the equip m...

Page 6: ...y if Customer provides a purchase order number credit card number or other method of payment acceptable to 3Com to be used if 3Com needs to charge Customer for the replacement as explained below The r...

Page 7: ...olve Radio TV Interference Problems This booklet is available from the U S Government Printing Office Washington DC 20402 Stock No 004 000 00345 4 In order to meet FCC emissions limits this equipment...

Page 8: ...f their respective holders General Environmental Statement It is the policy of 3Com Corporation to be environmentally friendly in all operations To uphold our policy we are committed to Establishing e...

Reviews: