1-12
C
HAPTER
1: O
VERVIEW
The server power supply has overcurrent protection on the +5 V output
and overvoltage protection on +5 V DC. The server’s total power
consumption is approximately 161 W maximum.
Weight
12.0 lb (5.5 kg)
Table 1-5 Electrical Requirements
Parameter
Requirement
Input voltage
115/230 VAC
47–63 Hz
Input voltage ranges 90 to 132 VAC
or 180 to 264
VAC
Either range accepted without user
switching
Maximum current
consumption
1.8 A
Fuse: 3 A, 250 V, fast-blow, 5 mm x 20
mm
Maximum power
consumption
161 W
Heat dissipation
550 BTU/h
Table 1-6 Environmental Requirements
Requirement
Parameter
Minimum
Maximum
Temperature:
Operating
41°F (5°C)
104°F (40°C)
Nonoperating
-4°F (-20°C)
140°F (60°C)
Altitude:
Operating
Sea level
15,000 ft. (4,572 m)
Nonoperating
Sea level
40,000 ft. (12,191 m)
Relative humidity:
Operating
20% noncondensing
80% noncondensing
Nonoperating
10% noncondensing
90% noncondensing
Table 1-4 Physical Dimensions
Attribute
Description
CS2500BookFile : Overview Page 12 Thursday, December 11, 1997 10:44 AM
Summary of Contents for CS/2500
Page 4: ...iv CS2500BookFile FrontMatter Page iv Thursday December 11 1997 10 44 AM ...
Page 10: ...x CS2500BookFile CS2500BookFileTOC Page x Thursday December 11 1997 10 44 AM ...
Page 16: ...4 ABOUT THIS GUIDE CS2500BookFile AboutThisGuide Page 4 Thursday December 11 1997 10 44 AM ...
Page 48: ...3 10 CHAPTER 3 STARTUP CS2500BookFile Startup Page 10 Thursday December 11 1997 10 44 AM ...
Page 114: ...6 INDEX CS2500BookFile CS2500BookFileIX Page 6 Thursday December 11 1997 10 44 AM ...