background image

C

ORE

B

UILDER

® 

5000 S

WITCH

M

ODULE

  Q

UICK

  S

TART

 

AND

  R

EFERENCE

7

The following figure shows the hub configured with a 
network management station on the LAN that is attached 
to SwitchModule port 2.6:

To manage the hub from the network management station 
in the previous figure:

1

Configure IP settings for virtual bridge 1 using the 
commands in the following example (values shown are 
sample values):

> set ip subnet_mask ff.ff.ff.00 vbridge 1

set ip ip_address 141.102.3.131 vbridge 1

>

 

set

 

ip default_gateway

 

141.102.3.2

 

vbridge 1

Assigning an IP address to a virtual bridge automatically 
enables the virtual bridge interface to the DMM.

2

Save the settings as follows:

save ip

You can now access the DMM from the network 
management station. You can also send SNMP and RMON 
requests to the DMM. From the DMM, you can manage 
any network, virtual bridge, or module in the 
CoreBuilder 5000 hub. 

If you have multiple subnetworks in your network, and 
you want to manage the hub in-band from each 
subnetwork, you must configure IP settings for each 
subnetwork. 

If you already have an in-band connection to the DMM 
and if you still want to add in-band connectivity through a 
SwitchModule port, do one of the following:

Before you establish an in-band DMM interface through 
the SwitchModule, assign the virtual bridge an IP 
address that is on a unique subnetwork.

Disable the existing in-band DMM interface.

SwitchModules in
slots 2, 3, and 4

NMS

LAN

DMM in
slot 1

For more information about IP configuration, see the 

CoreBuilder 5000 SwitchModule User Guide

 on the 

DocsOnCD

 documentation CD-ROM that comes with this 

product.

8.3

Creating an Additional Virtual Bridge

A virtual bridge is a user-defined group of SwitchModule 
ports. This group of ports operates as a single logical 
bridge. 

You can segment your network into more than one virtual 
bridge by creating new virtual bridges. You can assign any 
port on any SwitchModule to the new virtual bridge. 

The following figure shows a SwitchModule network that 
is configured with two virtual bridges:

To create the configuration in this figure:

1

Enter the commands in the following example (values 
shown are sample values): 

set bridge_port 3.1 vbridge 2

set bridge_port 3.2 vbridge 2

set bridge_port 4.all vbridge 2

2

Save the settings as follows:

save all

The new network configuration consists of two separate 
virtual bridges. Each virtual bridge maintains a separate 
Spanning Tree configuration. All ports on virtual bridge 2 
are enabled by default.

The two virtual bridges that are described in this example 
cannot send traffic to one another at this point without an 
external connection. (See Section 8.4.) However, you can 
manage all ports on both virtual bridges using the DMM or 
other supported network management software, such as 
3Com Transcend

®

 Network Control Services.

SwitchModules in
slots 2, 3, and 4

NMS

LAN

DMM in
slot 1

Virtual bridge 1
Virtual bridge 2

Summary of Contents for CoreBuilder 5000

Page 1: ...r later CoreBuilder 5000 Distributed Management Module Commands Guide for software Version v6 00 or later You can view these documents online with the 3Com DocsOnCD documentation CD ROM that comes wit...

Page 2: ...416SW 10 Slot Slots 9 and 10 are reserved for the CoreBuilder 5000 ATM Switch Control Point Module Model Number 3C96416SW 3 3 Software Prerequisites Before you install a new SwitchModule 1 Determine t...

Page 3: ...0 operational code to all SwitchModules in the hub 3 Download ATM SwitchModule software Version v3 00 operational code to all ATM Backbone SwitchModules in the hub The ATM SwitchModule model number is...

Page 4: ...tchModule User Guide CoreBuilder 5000 SwitchModule Quick Start and Reference this guide CoreBuilder 5000 SwitchModule Command Reference CoreBuilder 5000 SwitchModule Planning Chart CLASS 1 LED PRODUCT...

Page 5: ...t panel with one hand while you close each ejector handle Ensure that the SwitchModule remains fully seated in the backplane connector while you close the ejector handles 5 To secure the SwitchModule...

Page 6: ...col is enabled on virtual bridge 1 and on all SwitchModule ports Spanning Tree parameters are set to their default settings which are described in Chapter 7 in the CoreBuilder 5000 SwitchModule User G...

Page 7: ...able the existing in band DMM interface SwitchModules in slots 2 3 and 4 NMS LAN DMM in slot 1 For more information about IP configuration see the CoreBuilder 5000 SwitchModule User Guide on the DocsO...

Page 8: ...th this product You can also use a network management application such as 3Com Transcend Network Control Services to further configure SwitchModules See the appropriate network management documentatio...

Page 9: ...in chassis and connected to the PacketChannel backplane Off SwitchModule is not connected to the PacketChannel backplane or was inserted in slots 9 12 17 slot hub or 9 and 10 10 slot hub which are res...

Page 10: ...o connectors with 12 ports per connector for a total of 24 ports The following illustrations show these SwitchModules The X that follows the port numbers indicates a crossover port Port Status Activit...

Page 11: ...lows the port number indicates a crossover port CoreBuilder 5000 10BASE T modules use crossover ports This means that if you connect a 10BASE T SwitchModule port to another CoreBuilder 5000 10BASE T m...

Page 12: ...enabled and link is OK 1 Blink No light on receive fiber 2 Blinks Port received jabber 3 Blinks Port is partitioned 4 Blinks Remote fault Off Port or port functions are disabled Yellow On Heavy traff...

Page 13: ...On Port is enabled and link is OK Green Blinking Link failure or waiting for network connection Off Port or port functions are disabled Yellow On Heavy port traffic activity Yellow Blinking Normal po...

Page 14: ...dule is a Dual Attachment Concentrator DAC which is composed of 4 M ports and an A and B port pair that is connected to a single MAC 15 3 Optical Bypass Connector FDDI SwitchModules support one optica...

Page 15: ...Port is in full duplex mode Green Blinking Autonegotiation is determining the correct duplex setting Off Port is in half duplex mode Copyright 3Com Corporation 2000 All rights reserved 3Com the 3Com l...

Page 16: ...xhibits a defect in materials or workmanship within the first forty eight 48 hours of installation but no later than thirty 30 days after the date of purchase and this is verified by 3Com it will be c...

Reviews: